KROHNE

KROHNE H250-RR Variable Area Flow Meter

SKU · 33899 · H250-RR · Brand: KROHNE
Available
Quote on request
No online payment · add lines to RFQ BOM

H250/RR all-metal VA: ±1.6%; 10:1 (100:1 opt); to 400 °C / ~1000 barg. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
±1.6% of measured value (VDI/VDE 3513-2, qG=50%); optional precision calibration
Measuring Principle
Variable area (float) — all-metal H250 with M40 indicator
Variant
H250/RR low-flow cone/float combinations (DN15 / 1/2")
Turndown
10:1 standard; optional 100:1
Process Temperature
Up to −196…+400 °C depending on configuration / modules
Process Pressure
Up to ~1000 barg / 14500 psig depending on design
Download datasheet PDF

Fits all-metal variable-area flow where you need a KROHNE H250/RR low-flow cone with M40 indicator—±1.6% of measured value class and process temperatures to −196…+400 °C depending on configuration.

Key advantages

  • Principle — Variable area (float); all-metal H250 with M40 indicator
  • Variant — H250/RR low-flow cone/float (DN15 / ½")
  • Accuracy — ±1.6% MV (VDI/VDE 3513-2, qG=50%); optional precision cal
  • Turndown — 10:1 standard; optional 100:1
  • Process — To −196…+400 °C; pressure to ~1000 barg class (design dependent)

Typical applications

  • Clean liquid / gas low-flow indication.
  • High-T / high-P metal VA services.
  • Purge and sample lines needing metal tubes.

Selection guide

  • Float / cone for fluid
  • Indicator / switches / 4–20 mA
  • Material / gasket
  • Turndown option

Common mistakes

  • Using on abrasive slurries.
  • Ignoring density/viscosity vs float sizing.
  • Skipping optional precision calibration when ±1.6% is not enough.

When to RFQ / what to tell us

  1. Fluid, flow, T/P.
  2. Materials, outputs, quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU33899
BrandKROHNE
ModelH250-RR Variable Area Flow Meter
Product typeVariable Area Flow Meter
Measuring principleVariable area (float) — all-metal H250 with M40 indicator
VariantH250/RR low-flow cone/float combinations (DN15 / 1/2")
MediumClean liquids and gases (non-abrasive)
Accuracy±1.6% of measured value (VDI/VDE 3513-2, qG=50%); optional precision calibration
Turndown10:1 standard; optional 100:1
Process temperatureUp to −196…+400 °C depending on configuration / modules
Process pressureUp to ~1000 barg / 14500 psig depending on design

Documents

FAQ

Q: Accuracy? A: ±1.6% of measured value class (VDI/VDE 3513-2).

Q: Turndown? A: 10:1 standard; optional 100:1.

Q: What should I send for a quote? A: Fluid/flow/T/P, materials, quantity, ship-to.

Links

ParameterValue
Accuracy±1.6% of measured value (VDI/VDE 3513-2, qG=50%); optional precision calibration
Measuring PrincipleVariable area (float) — all-metal H250 with M40 indicator
VariantH250/RR low-flow cone/float combinations (DN15 / 1/2")
Turndown10:1 standard; optional 100:1
Process TemperatureUp to −196…+400 °C depending on configuration / modules
Process PressureUp to ~1000 barg / 14500 psig depending on design
ConnectionsFlange DN15…150 / ½…6"; also NPT, G, hygienic
Outputs ModulesMechanical indicator; optional NAMUR/reed limits, 4…20 mA HART, FF/PA, totalizer LCD
ProtectionIP66/IP68 / NEMA 4X/6; optional IP69K
ExUniversal Ex concept (Ex i / Ex d / Ex t / Ex nA)
ApplicationLow-flow liquid/gas process measurement without auxiliary power