Hedland Water and Other Fluid Flow Meters
Hedland VA flow meters: water/emulsion; ±2% FS; to 3500/6000 psi; any position. RFQ.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits direct-reading water-based flow indication where you need a Hedland variable-area meter. Flow meter for water-based fluids and water-oil emulsions with accuracy ±2% of full scale (±7% FS for ¼ in meters), repeatability ±1%, temperature −20 to +240 °F standard class, aluminum/brass to 3,500 psi or stainless to 6,000 psi class (size-dependent), 1.0 S.G. calibration, install-in-any-position with 360° rotatable guard/scale, and SAE/NPTF/BSPP/Code 61/62 options.
Key advantages
- Accuracy — ±2% FS (±7% on ¼ in)
- Repeatability — ±1%
- Pressure — To 3500/6000 psi class
- Install — Any position; no straighteners
- Bodies — Al / brass / SS
Typical applications
- Water-based hydraulic flow.
- Emulsion circuit indication.
- Direct-reading VA meters.
Selection guide
- Body material
- Thread / flange
- Flow range / size
Common mistakes
- Wrong S.G. assumption.
- ¼ in accuracy class ignored.
- Pressure above body rating.
When to RFQ / what to tell us
- Size/material/ports.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 43069 |
| Brand | Hedland |
| Model | Water and Other Fluid Flow Meters |
| Product type | Variable Area Flow Meter |
| Type | Direct-reading variable-area flow meter for water-based fluids / water-oil emulsions (Hedland) |
| Accuracy | +/-2% of full scale (+/-7% FS for 1/4 in meters) |
| Repeatability | +/-1% |
| Temperature range | -20 to +240 F (-29 to +116 C) standard class |
| Pressure rating | Aluminum/brass to 3,500 psi/241 bar class; stainless to 6,000 psi/414 bar class (size-dependent) |
| Calibration | Calibrated for 1.0 S.G.; for 80/20 and other water/oil emulsions |
| Installation | Install in any position; 360 degree rotatable guard/scale; no flow straighteners required |
| Materials | Anodized aluminum, brass, or stainless body options; Viton pressure seals; polycarbonate guard |
Documents
FAQ
Q: Accuracy? A: ±2% FS (±7% for ¼ in).
Q: Install position? A: Any position.
Q: What should I send for a quote? A: Size/material/ports, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | +/-2% of full scale (+/-7% FS for 1/4 in meters) |
| Type | Direct-reading variable-area flow meter for water-based fluids / water-oil emulsions (Hedland) |
| Repeatability | +/-1% |
| Temperature Range | -20 to +240 F (-29 to +116 C) standard class |
| Pressure Rating | Aluminum/brass to 3,500 psi/241 bar class; stainless to 6,000 psi/414 bar class (size-dependent) |
| Calibration | Calibrated for 1.0 S.G.; for 80/20 and other water/oil emulsions |
| Installation | Install in any position; 360 degree rotatable guard/scale; no flow straighteners required |
| Materials | Anodized aluminum, brass, or stainless body options; Viton pressure seals; polycarbonate guard |
| Threads | SAE J1926/1, NPTF, BSPP ISO1179, Code 61/62 flange options |
| Document | Hedland Variable Area Flow Meters catalog — Water-based Fluids section (Badger Meter OEM catalog) |