Panametrics air.IQ Moisture Analyzer Package

SKU · 39531 · air.IQ · Brand: Panametrics
Available
Quote on request
No online payment · add lines to RFQ BOM

air.IQ: −110…+20 °C dew/frost; 0–200 psig; IP66 SS; dew.IQ + IQ.probe. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
–110 to +20 °C dew/frost point (system); dew.IQ overall –110 to +60 °C capability; standard –80 to +20 °C with data to –110 °C
Accuracy
Calibrated accuracy at 77 °F (25 °C): ±2 °C above –100 °C; ±3 °C below –100 °C dew/frost point
Output
Isolated 4–20 mA / 0–20 mA / 0–2 V switch-selectable; two SPDT alarm relays; fail-safe fault relay
Supply
100–240 VAC 50/60 Hz or 24 VDC option
Process connection
1/4 in or 6 mm fittings (variant-dependent)
Display
128 × 64 matrix LCD (dew point °C/°F, ppmv with constant pressure input)
Download datasheet PDF

Fits clean inert-gas moisture measurement where you need a Panametrics air.IQ—wall-mounted IP66/NEMA 4X stainless package with dew.IQ display, IQ.probe, and sample system for −110 to +20 °C dew/frost point at up to 200 psig.

Key advantages

  • Moisture — −110…+20 °C dew/frost, non-condensing
  • Pressure — 0–200 psig process
  • Package — Analyzer + probe + needle valve/filter/gauge/rotameter
  • I/O — 4–20 mA / 0–2 V; two alarms; fail-safe fault relay
  • Enclosure — IP66 / NEMA 4X SS with window; 100–240 VAC or 24 VDC

Typical applications

  • Compressed air dryer outlet.
  • N2 / argon inert gas moisture.
  • Plastics / pharma dry air panels.

Selection guide

  • ¼" vs 6 mm fittings
  • AC vs 24 VDC
  • SI display units

Common mistakes

  • Condensing samples into probe.
  • Hydrocarbon-laden gas without proper sample conditioning.
  • Exceeding 200 psig inlet.

When to RFQ / what to tell us

  1. Power/fittings.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU39531
BrandPanametrics
Modelair.IQ
Product typeMoisture Analyzer Package
TypePackaged moisture analyzer + sample system (air.IQ)
Moisture−110…+20 °C dew/frost point, non-condensing
Pressure0–200 psig process
Sample temp0…+50 °C
GasesClean inert gases (air, N2, argon class)
Outputs4–20 mA / 0–2 V; two alarm relays; fail-safe fault relay
EnclosureIP66 / NEMA 4X stainless with window; 100–240 VAC or 24 VDC

Documents

FAQ

Q: Moisture range? A: −110 to +20 °C dew/frost point.

Q: Max pressure? A: 200 psig.

Q: What should I send for a quote? A: Power/fittings, quantity, ship-to.

Links

ParameterValue
Measuring range–110 to +20 °C dew/frost point (system); dew.IQ overall –110 to +60 °C capability; standard –80 to +20 °C with data to –110 °C
AccuracyCalibrated accuracy at 77 °F (25 °C): ±2 °C above –100 °C; ±3 °C below –100 °C dew/frost point
OutputIsolated 4–20 mA / 0–20 mA / 0–2 V switch-selectable; two SPDT alarm relays; fail-safe fault relay
Supply100–240 VAC 50/60 Hz or 24 VDC option
Process connection1/4 in or 6 mm fittings (variant-dependent)
Display128 × 64 matrix LCD (dew point °C/°F, ppmv with constant pressure input)
ApprovalsEMC 2004/108/EC; LVD 2006/95/EC; IP66 EN60529; NEMA 4X UL508A
Sensor typeThin-film aluminum oxide (IQ.probe) with stainless sensor shield
Repeatability±0.2 °C above –100 °C; ±0.5 °C below –100 °C
Process Pressure0 to 200 psig (0 to 1,379 kPa) sample inlet
Sample Temperature0 to +50 °C (32 to 122 °F)
EnclosureWall-mounted IP66 / NEMA 4X stainless steel with clear window; IK10 impact
Sample GasesInert gases such as air, nitrogen, or argon (safe-area)
Data Logging32 GB MicroSD capacity (4 GB card included)
Warm UpMeets specified accuracy within three minutes