Wilkerson DR1920 Duplex Lift Station Back-Up Pump Controller
DR1920 backup duplex pump controller; DIN-rail; 10 A relays; 85–250 VAC. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
DIN-rail backup controller that monitors a high/high-high level switch and starts one or two pumps with adjustable staging and run-on timers when the primary level control fails.
Key advantages
- Backup duplex control — starts Pump 1 on alarm, stages Pump 2 after Timer 1, then run-on via Timer 2 after alarm clears.
- Impedance switch sense — monitors NO/NC contacts already in the system (closed <500 Ω / open ≥1500 Ω @ 20 kHz) independent of voltage presence.
- Dual 10 A Form A relays — plus isolated NPN outputs (30 mA) per pump; reset input.
- Wide AC power — 85…250 VAC ±10%, 50/60 Hz, 2 VA; UL/cUL Recognized; 5-year warranty.
Typical applications
- Sewage/storm lift stations needing a backup to the primary level controller.
- Wet wells where high-high float/switch must force pumps to prevent overflow.
- Retrofits that wire in parallel across an existing alarm switch.
Selection guide
- Power — 85…250 VAC ±10%, 50/60 Hz, 2 VA.
- Alarm inputs — Impedance NO/NC switch input; auxiliary isolated switch or OC NPN; jumper for open- or close-to-alarm.
- Outputs — Two NO 10 A Form A relays; two optically isolated NPN (sink/source 30 mA).
- Timers — Timer 1 (Pump 2 delay): 2…126 s in 2 s steps; Timer 2 (run time): 5…1,275 s in 5 s steps; binary DIP switches.
- Indicators — Pump 1/2 LEDs (green OFF / red RUN).
- Enclosure — DIN-rail; ~3.9 H × 4.48 D × 0.87 W in.; plug-in screw terminals.
Common mistakes
- Using it as the only primary level controller — it is a backup to high-high alarm.
- Mis-setting open-vs-close-to-alarm jumper for the float logic.
- Undersizing the 10 A relay contacts for motor starters (use as pilot duty appropriately).
- Forgetting periodic exercise via digital/reset inputs.
- Automation & control
When to RFQ / what to tell us
- Pump starter interface (relay pilot vs OC); voltage.
- Float/switch type and open- vs close-to-alarm preference.
- Desired Timer 1 / Timer 2 settings; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 31900 |
| Brand | Wilkerson Instrument |
| Model | DR1920 |
| Product type | duplex lift-station backup pump controller |
| Supply voltage | 85 to 250 VAC ±10%, 50/60 Hz, 2 VA |
| Output signal | Two NO 10 A Form A relays; two isolated NPN 30 mA |
| Process connection | DIN-rail mount; plug-in screw terminals |
| Approvals | UL/cUL Recognized |
| Notes | Specs from wici.com DR1920 page and DR1920 catalog PDF. |
Documents
FAQ
Q: Is this a primary duplex controller? A: No — it is a backup that acts on the high-high alarm when the primary level control fails.
Q: Can it parallel an existing float already wired to 120 VAC? A: Yes — the impedance input is designed to monitor switch state regardless of voltage presence across the contacts (within OEM guidance).
Q: What should I send for a quote? A: Starter interface, switch logic, timer targets, quantity, ship-to. Compatible with systems using Wilkerson DR1920 if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Status | Specs pending OEM datasheet merge |