Wilkerson DR1920 Duplex Lift Station Back-Up Pump Controller

SKU · 31900 · Wilkerson Instruments DR1920 Duplex Lift Station Back-Up Pump Controller
Available
Quote on request
No online payment · add lines to RFQ BOM

DR1920 backup duplex pump controller; DIN-rail; 10 A relays; 85–250 VAC. RFQ + selection help.

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Range
—
Accuracy
—
Output
—

DIN-rail backup controller that monitors a high/high-high level switch and starts one or two pumps with adjustable staging and run-on timers when the primary level control fails.

Key advantages

  • Backup duplex control — starts Pump 1 on alarm, stages Pump 2 after Timer 1, then run-on via Timer 2 after alarm clears.
  • Impedance switch sense — monitors NO/NC contacts already in the system (closed <500 Ω / open ≥1500 Ω @ 20 kHz) independent of voltage presence.
  • Dual 10 A Form A relays — plus isolated NPN outputs (30 mA) per pump; reset input.
  • Wide AC power — 85…250 VAC ±10%, 50/60 Hz, 2 VA; UL/cUL Recognized; 5-year warranty.

Typical applications

  • Sewage/storm lift stations needing a backup to the primary level controller.
  • Wet wells where high-high float/switch must force pumps to prevent overflow.
  • Retrofits that wire in parallel across an existing alarm switch.

Selection guide

  • Power — 85…250 VAC ±10%, 50/60 Hz, 2 VA.
  • Alarm inputs — Impedance NO/NC switch input; auxiliary isolated switch or OC NPN; jumper for open- or close-to-alarm.
  • Outputs — Two NO 10 A Form A relays; two optically isolated NPN (sink/source 30 mA).
  • Timers — Timer 1 (Pump 2 delay): 2…126 s in 2 s steps; Timer 2 (run time): 5…1,275 s in 5 s steps; binary DIP switches.
  • Indicators — Pump 1/2 LEDs (green OFF / red RUN).
  • Enclosure — DIN-rail; ~3.9 H × 4.48 D × 0.87 W in.; plug-in screw terminals.

Common mistakes

  • Using it as the only primary level controller — it is a backup to high-high alarm.
  • Mis-setting open-vs-close-to-alarm jumper for the float logic.
  • Undersizing the 10 A relay contacts for motor starters (use as pilot duty appropriately).
  • Forgetting periodic exercise via digital/reset inputs.
  • Automation & control

When to RFQ / what to tell us

  1. Pump starter interface (relay pilot vs OC); voltage.
  2. Float/switch type and open- vs close-to-alarm preference.
  3. Desired Timer 1 / Timer 2 settings; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU31900
BrandWilkerson Instrument
ModelDR1920
Product typeduplex lift-station backup pump controller
Supply voltage85 to 250 VAC ±10%, 50/60 Hz, 2 VA
Output signalTwo NO 10 A Form A relays; two isolated NPN 30 mA
Process connectionDIN-rail mount; plug-in screw terminals
ApprovalsUL/cUL Recognized
NotesSpecs from wici.com DR1920 page and DR1920 catalog PDF.

Documents

FAQ

Q: Is this a primary duplex controller? A: No — it is a backup that acts on the high-high alarm when the primary level control fails.

Q: Can it parallel an existing float already wired to 120 VAC? A: Yes — the impedance input is designed to monitor switch state regardless of voltage presence across the contacts (within OEM guidance).

Q: What should I send for a quote? A: Starter interface, switch logic, timer targets, quantity, ship-to. Compatible with systems using Wilkerson DR1920 if you need a drop-in check — we do not claim authorized-dealer status.

Links

ParameterValue
StatusSpecs pending OEM datasheet merge