Waltron 9131C Sodium Analyzer
9131C sodium analyzer 0.10 ppb–10 ppm; dual 4–20 mA; Modbus. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Ultra-compact online sodium analyzer for ultrapure water with color touchscreen, internal temperature compensation, and dual isolated 4–20 mA outputs.
Key advantages
- Wide sodium range — 0.10 ppb…10 ppm (display 0.01 ppb…10 ppm).
- ±5% of reading or ±0.1 ppb — whichever is greater, within ±5 °C of calibration temperature.
- Dual 4–20 mA + Modbus — RS-232 & RS-485 Modbus RTU; three voltage-free alarm contacts.
- Compact panel/wall package — 40×30×20 cm; ~9 kg; color touchscreen and internal datalogger with USB.
Typical applications
- Make-up water, condensate, boiler feedwater, and steam sodium monitoring.
- Ultrapure water loops needing low-ppb sodium with manual calibration assist.
- Single-channel installs using ammonium hydroxide or DIPA buffers.
Selection guide
- Range / accuracy — 0.10 ppb…10 ppm; ±5% of reading or ±0.1 ppb (whichever greater) within ±5 °C of cal temperature.
- Response — ~90% of 1–10 ppb step <4 min; 90% of 100–1 ppb step ~5 min.
- Outputs — Two isolated 4–20 mA; RS-232 & RS-485 Modbus RTU; three alarm contacts (2 A / 250 VAC non-inductive).
- Power — 90…250 VAC.
- Sample — 5…55 °C; 150…400 ml/min; 5…30 psig (0.35…2.07 bar); filtered to 60 μm; free of film-forming compounds.
- Ambient — 0…55 °C.
- Mounting — Panel / wall; sample ¼ in. OD Swagelok.
- Buffer — Ammonium hydroxide or DIPA.
- Calibration — Manual with menu assist; internal temperature compensation.
Common mistakes
- Feeding unfiltered or film-forming samples — OEM asks for 60 μm filtration and clean chemistry.
- Expecting multi-stream without confirming single-channel scope.
- Ignoring sample pressure/flow window (5…30 psig / 150…400 ml/min).
- Ordering without stating buffer preference (ammonium hydroxide vs DIPA).
- Analytical / water quality · Liquid analysis buying guide
When to RFQ / what to tell us
- Expected sodium range (ppb/ppm) and sample temperature/pressure/flow.
- Buffer preference; alarm/analog scaling needs.
- Mounting (panel/wall), power region, quantity, ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 174214 |
| Brand | Waltron |
| Model | 9131C |
| Product type | sodium analyzer |
| Measuring range | 0.10 ppb to 10 ppm (displays 0.01 ppb to 10 ppm) |
| Accuracy | ±5% of reading or ±0.1 ppb (whichever greater) within ±5 °C of calibration temperature |
| Output signal | Two isolated 4–20 mA; RS-232 & RS-485 Modbus RTU; three voltage-free alarms |
| Supply voltage | 90 to 250 VAC |
| Process connection | 0.635 cm (1/4 in.) OD Swagelok sample |
| Ambient temperature | 0 to 55 °C (32 to 131 °F) |
| Sample temperature | 5 to 55 °C (40 to 130 °F) |
| Weight | 9 kg (20 lb) |
| Dimensions | 40 × 30 × 20 cm (16 × 12 × 8 in.) |
| Notes | Specs from waltron.net 9131C product page. Single-channel. Reagents/electrodes are consumables. |
Documents
FAQ
Q: What sodium range does the 9131C cover? A: Analysis 0.10 ppb…10 ppm (display down to 0.01 ppb). Confirm your expected ppb band in the RFQ.
Q: Multi-stream? A: Published as single-channel. Ask if you need multi-stream options in the family.
Q: What should I send for a quote? A: Range, sample T/P/flow, buffer, mounting, power, quantity. Compatible with systems using Waltron 9131C if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Status | Specs pending OEM datasheet merge |