Image unavailable
Image unavailable
Druck
Druck DPI 880 Multi-Function Calibrator
Quote on request
No online payment · add lines to RFQ BOM
mA/V/ohms/Hz/RTD/TC + IDOS pressure; dual readings. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
mA, mV/V, ohms, frequency/pulses, RTD, thermocouple; pressure via IDOS UPM modules
Accuracy
Electrical accuracies per DPI 880 datasheet tables; pressure accuracy per IDOS module
Output
mA source/measure with 24 V loop power; HART 250 Ω resistor; switch and leak test
Supply
Internal batteries; 24 V loop power for transmitters
Process connection
IDOS universal pressure module interface
Housing
Rugged handheld elastomer-protected enclosure
Fits multifunction field calibration where you need a Druck DPI 880 to measure/source electrical signals, RTD/TC, and optional IDOS pressure with simultaneous dual readings.
Key advantages
- Signals — mA, mV/V, ohms, frequency/pulses, RTD, thermocouple; pressure via IDOS UPM
- Operation — Measure, source and simulate; simultaneous dual readings
- Loop — mA source/measure with 24 V loop power; HART 250 Ω resistor; switch and leak test
- Memory — Up to 1,000 point data storage
- Form — Rugged handheld elastomer-protected enclosure
Typical applications
- Multi-signal instrument technicians carrying one handheld.
- Temperature and electrical calibration with optional pressure modules.
- Switch test and leak-test workflows.
Selection guide
- IDOS pressure — Which UPM ranges if pressure is needed
- Primary signals — Electrical vs TC/RTD focus
- Accessories — Leads, modules, pumps
- Data storage — 1,000-point logging use
Common mistakes
- Assuming pressure modules are included — IDOS UPM is optional.
- Expecting documenting HART communicator features beyond loop resistor support.
- Omitting TC/RTD types on the RFQ.
When to RFQ / what to tell us
- Electrical/TC/RTD needs; IDOS pressure ranges.
- Accessories and logging needs.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 18310 |
| Brand | Druck |
| Model | Druck DPI 880 Multi-Function Calibrator |
| Product type | Multifunction Calibrator |
| Measuring range | mA, mV/V, ohms, frequency/pulses, RTD, thermocouple; pressure via IDOS UPM modules |
| Functions | Measure, source and simulate electrical signals; simultaneous dual readings |
| Accuracy | Electrical accuracies per DPI 880 datasheet tables; pressure accuracy per IDOS module |
| Output / loop | mA source/measure with 24 V loop power; HART 250 Ω resistor; switch and leak test |
| Supply | Internal batteries; 24 V loop power for transmitters |
| Communication | HART loop resistor support; desktop connectivity per system |
| Display | Backlit dual-parameter display |
| Data logging | Up to 1,000 point data storage |
| Housing | Rugged handheld elastomer-protected enclosure |
Documents
FAQ
Q: Does it include pressure? A: Pressure is via optional IDOS UPM modules.
Q: Dual readings? A: Yes — simultaneous dual-parameter display.
Q: What should I send for a quote? A: Signals/modules, accessories, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | mA, mV/V, ohms, frequency/pulses, RTD, thermocouple; pressure via IDOS UPM modules |
| Accuracy | Electrical accuracies per DPI 880 datasheet tables; pressure accuracy per IDOS module |
| Output | mA source/measure with 24 V loop power; HART 250 Ω resistor; switch and leak test |
| Supply | Internal batteries; 24 V loop power for transmitters |
| Process connection | IDOS universal pressure module interface |
| Housing | Rugged handheld elastomer-protected enclosure |
| Ambient temperature | Operating per Druck DPI 880 datasheet environmental section |
| Display | Backlit dual-parameter display |
| Communication | HART loop resistor support; desktop connectivity per system |
| Approvals | CE and regional markings per datasheet |
| Mounting | Handheld field/workshop multifunction calibrator |
| Notes | Replacement harvest for skipped 49009 (duplicate of 39101 DPI620 Genii Package). |
| Functions | Measure, source and simulate electrical signals; simultaneous dual readings |
| Data Logging | Up to 1,000 point data storage |