Fluke

Fluke 712B RTD Temperature Calibrator

SKU · 40218 · 712B · Brand: Fluke
Available
Quote on request
No online payment · add lines to RFQ BOM

RTD/ohms calibrator: 13 RTD types + 0–4000 Ω, isolated mA measure, IP52 handheld. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
13 RTD types + resistance measure/source (0–4000 Ω classes); simultaneous isolated mA measure 0–24 mA class
Accuracy
Ohms measure 0.015% + 0.05 Ω (0–400 Ω) / 0.015% + 0.5 Ω (400–4000 Ω); mA per datasheet; 1-year specs 18–28 °C
Output
RTD / ohms source; simultaneous mA measure channel
Supply
4× AA NEDA 1.5A IEC LR6
Electrical connection
RTD banana/mini; banana for mA
Protection
IP52 (IEC 60529)
Download datasheet PDF

Fits field RTD and resistance calibration where you need to measure/source 13 RTD types plus resistance (0–4000 Ω classes) with a simultaneous isolated mA measure channel — companion to the 714B thermocouple calibrator, not a full documenting multi-function unit.

Key advantages

  • 13 RTD types + ohms — measure/source RTD and 0–4000 Ω classes on one handheld.
  • Isolated mA measure — simultaneous 0–24 mA class channel for transmitter loops.
  • Ohms accuracy published — 0.015% + 0.05 Ω (0–400 Ω) / 0.015% + 0.5 Ω (400–4000 Ω).
  • IP52 field kit — 4× AA; magnetic hanger; dual backlit inputs; −10…+50 °C operating.

Typical applications

  • Field RTD and resistance calibration of temperature transmitters.
  • Loop checks needing simultaneous isolated mA measure.
  • Companion use with TC-focused 714B on the same cart.

Selection guide

  • Measuring / source range — 13 RTD types + resistance measure/source (0–4000 Ω classes); simultaneous isolated mA measure 0–24 mA class.
  • Accuracy — Ohms measure 0.015% + 0.05 Ω (0–400 Ω) / 0.015% + 0.5 Ω (400–4000 Ω); mA per OEM documentation; 1-year specs 18–28 °C.
  • Output / channels — RTD / ohms source; simultaneous mA measure channel. Dual inputs, backlit display.
  • Supply — 4× AA NEDA 1.5A IEC LR6.
  • Electrical connection — RTD banana/mini; banana for mA.
  • IP — IP52 (IEC 60529).
  • Ambient — Operating −10…+50 °C; storage −30…+60 °C; operating altitude 2000 m.
  • Mounting — Handheld; magnetic hanger included.
  • Weight / size — 515 g; 52.5 × 84 × 188.5 mm (H×W×L).
  • Approvals — IEC 61010-1; IEC 61326-1 Portable; MIL-T-28800E Class 2 vibration.

Common mistakes

  • Expecting thermocouple source/measure — 712B is RTD/ohms focused; use 714B (or similar) for TC/mV.
  • Using 1-year ohms accuracy outside 18–28 °C without checking extended ambient tables.
  • Assuming the mA channel sources loop current — datasheet lists simultaneous isolated mA measure.
  • Ignoring IP52 limits in wet or dusty plant areas beyond that rating.
  • Ordering without confirming RTD wiring (2/3/4-wire) and connector set for your sensors.
  • Calibration instruments · Calibration buying guide

When to RFQ / what to tell us

  1. RTD types needed, ohms span class (0–400 vs 400–4000 Ω), and required tolerances.
  2. mA measure need, ambient, and connector preferences (banana/mini).
  3. Quantity, ship-to, and QA docs beyond the included traceable certificate.

Request a Quote · Get selection help

Specs

SpecValue
SKU40218
BrandFluke
Model712B
Product typecalibrator
Measuring range13 RTD types + resistance measure/source (0–4000 Ω classes); simultaneous isolated mA measure 0–24 mA class
AccuracyOhms measure 0.015% + 0.05 Ω (0–400 Ω) / 0.015% + 0.5 Ω (400–4000 Ω); mA per OEM documentation; 1-year specs 18–28 °C
Output / functionsRTD / ohms source; simultaneous mA measure channel
Supply4× AA NEDA 1.5A IEC LR6
Electrical connectionRTD banana/mini; banana for mA
IP ratingIP52 (IEC 60529)
Ambient temperatureOperating −10…+50 °C; storage −30…+60 °C; operating altitude 2000 m
DisplayDual inputs, backlit display
ApprovalsIEC 61010-1; IEC 61326-1 Portable; MIL-T-28800E Class 2 vibration
MountingHandheld; magnetic hanger included
Weight515 g
NotesSize (H×W×L) 52.5 × 84 × 188.5 mm. Traceable certificate of calibration included per OEM. Shared datasheet with 714B.

Documents

FAQ

Q: Does 712B do thermocouples? A: No — 712B is RTD/ohms with isolated mA measure. For TC/mV see 714B (shared datasheet family).

Q: What ohms accuracy should I plan for? A: 0.015% + 0.05 Ω (0–400 Ω) / 0.015% + 0.5 Ω (400–4000 Ω) at 1-year, 18–28 °C.

Q: What should I send for a quote? A: RTD types, ohms class, mA need, ambient, quantity. Compatible with systems using Fluke 712B — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range13 RTD types + resistance measure/source (0–4000 Ω classes); simultaneous isolated mA measure 0–24 mA class
AccuracyOhms measure 0.015% + 0.05 Ω (0–400 Ω) / 0.015% + 0.5 Ω (400–4000 Ω); mA per datasheet; 1-year specs 18–28 °C
OutputRTD / ohms source; simultaneous mA measure channel
Supply4× AA NEDA 1.5A IEC LR6
Electrical connectionRTD banana/mini; banana for mA
ProtectionIP52 (IEC 60529)
Ambient temperatureOperating −10…+50 °C; storage −30…+60 °C; operating altitude 2000 m
DisplayDual inputs, backlit display
ApprovalsIEC 61010-1; IEC 61326-1 Portable; MIL-T-28800E Class 2 vibration
MountingHandheld; magnetic hanger included
NotesSize (H×W×L) 52.5 × 84 × 188.5 mm. Traceable certificate of calibration included per OEM. Shared datasheet with 714B.
Weight515 g