Image unavailable
Image unavailable
Fluke
Fluke 725 Multifunction Process Calibrator
Quote on request
No online payment · add lines to RFQ BOM
Multifunction cal; V/mA/TC/RTD/Hz; 0.02%; 24 V loop. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Display
Split measure/source backlight display; store test setups
Approvals
CE
Functions
Measure and source V, mA, ohms, frequency/CPM, RTDs, thermocouples; pressure via 750P modules
Voltage Range
0–100 mV / 0–10 V source; 0–30 V measure; accuracy 0.02% rdg + 2 LSD
Current Range
0–24 mA measure/source; 0.02% rdg + 2 LSD; max load 1000 Ω
Resistance Range
15 Ω to 3200 Ω
Fits everyday process calibration where you need a Fluke 725 measuring and sourcing V, mA, TC, RTD, frequency and pressure (via 750P) with 0.02% + 2 counts class DC accuracy and 24 V loop supply.
Key advantages
- Signals — Measure/source V, mA, TC, RTD, frequency; pressure via 750P
- Accuracy — DC V/I 0.02% + 2 counts
- Loop — 24 V loop supply; dual channel
- Range class — 30 V DC / 24 mA
- Form — Handheld dual-display process calibrator
Typical applications
- Transmitter mA/V checks.
- TC/RTD instrument source/read.
- Pressure cal with 750P modules.
Selection guide
- Vs 726/754 — Accuracy/HART documenting
- Pressure modules — Ranges
- TC/RTD set — Types needed
- Dual channel — Simultaneous measure/source
Common mistakes
- Expecting built-in HART documenting (see 754).
- Wrong pressure module.
- Ignoring loop current budget.
When to RFQ / what to tell us
- Modules/accessories; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 32732 |
| Brand | Fluke |
| Model | 725 |
| Product type | Process Calibrator |
| Type | Multifunction process calibrator |
| Signals | Measure/source V, mA, TC, RTD, frequency; pressure via 750P modules |
| Range | 30 V DC, 24 mA class |
| Accuracy | DC voltage/current 0.02% + 2 counts |
| Loop | 24 V loop supply; dual channel |
| Form | Handheld dual-display process calibrator |
Documents
FAQ
Q: Accuracy? A: DC voltage/current 0.02% + 2 counts class.
Q: HART documenting? A: Use Fluke 754 when documenting HART is required.
Q: What should I send for a quote? A: Modules, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Display | Split measure/source backlight display; store test setups |
| Approvals | CE |
| Functions | Measure and source V, mA, ohms, frequency/CPM, RTDs, thermocouples; pressure via 750P modules |
| Voltage Range | 0–100 mV / 0–10 V source; 0–30 V measure; accuracy 0.02% rdg + 2 LSD |
| Current Range | 0–24 mA measure/source; 0.02% rdg + 2 LSD; max load 1000 Ω |
| Resistance Range | 15 Ω to 3200 Ω |
| Frequency Range | 2–1000 CPM; 1–1100 Hz; 1–10 kHz |
| Loop Supply | 24 V DC loop power with simultaneous mA measurement |
| Thermocouples | J, K, T, E, R, S, B, L, U, N, C (measure/source) |
| Rtd Types | Ni120, Pt100-385/3926/3916, Pt200/500/1000-385 (2/3/4-wire) |
| Pressure | Compatible with Fluke 750Pxx pressure modules (50 types) |
| Power | Four AA alkaline; typical 25 h battery life |
| Size Weight | 96 × 200 × 47 mm; 650 g |
| Special Features | Auto step/ramp; remote interface; simultaneous mA + pressure for I/P tests |