Image unavailable
Image unavailable
Transmille
Transmille 3050A Multi-Product Calibrator
Quote on request
No online payment · add lines to RFQ BOM
3050A: DC/AC V/I, R, C, freq, TC sim; ~50 ppm DC V class. RFQ options + workload.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Type
Precision multi-product calibrator (Transmille 3050A / 3000A Series)
Dc Voltage
0–202 mV to 200–1025 V ranges (extended specifications V1.60)
Functions
DC/AC voltage, DC/AC current, resistance, capacitance, frequency, thermocouple simulation
Line Power
Selectable 110 V / 230 V; variation −6% / +10%
Connections
4 mm safety sockets for voltage/2-wire resistance and low-current ≤2 A
Dc Voltage Accuracy
1-year total accuracy class ~50 ppm of setting + offset (range-dependent)
Fits bench multiproduct calibration where you need a Transmille 3050A covering DC/AC voltage and current, resistance, capacitance, frequency, and thermocouple simulation in one chassis.
Key advantages
- Functions — DC/AC V, DC/AC I, resistance, capacitance, frequency, TC simulation
- DC voltage — Ranges from mV class through ~1025 V (extended specs)
- Accuracy class — ~50 ppm of setting + offset (1-year, function dependent)
- Line power — Selectable 110 / 230 V
- Connections — 4 mm safety sockets for voltage / 2-wire R and low current ≤2 A
Typical applications
- DMM / clamp calibration benches.
- Process meter shops.
- Lab multiproduct workload.
Selection guide
- Workload — Max V/I and TC types
- Options — Amplifiers / adapters
- Line voltage — 110 vs 230
- Software — Automation needs
Common mistakes
- Overlooking current-amplifier needs above onboard ranges.
- Skipping warm-up before accuracy checks.
- Ignoring 1-year vs 90-day specs.
When to RFQ / what to tell us
- Functions needed, options, line voltage.
- Quantity, ship-to, calibration cert.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 33237 |
| Brand | Transmille |
| Model | 3050 Multi-Product Calibrator |
| Product type | Multiproduct Calibrator |
| Type | Precision multi-product calibrator (Transmille 3050A / 3000A Series) |
| DC voltage | 0–202 mV to 200–1025 V ranges (extended specifications V1.60) |
| Functions | DC/AC voltage, DC/AC current, resistance, capacitance, frequency, thermocouple simulation |
| Line power | Selectable 110 V / 230 V; variation −6% / +10% |
| Connections | 4 mm safety sockets for voltage/2-wire resistance and low-current ≤2 A |
| DC V accuracy | 1-year total accuracy class ~50 ppm of setting + offset (range-dependent) |
Documents
FAQ
Q: TC simulation? A: Yes — thermocouple simulation is part of the 3050A function set.
Q: Line power? A: Selectable 110 V / 230 V.
Q: What should I send for a quote? A: Workload/options, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Type | Precision multi-product calibrator (Transmille 3050A / 3000A Series) |
| Dc Voltage | 0–202 mV to 200–1025 V ranges (extended specifications V1.60) |
| Functions | DC/AC voltage, DC/AC current, resistance, capacitance, frequency, thermocouple simulation |
| Line Power | Selectable 110 V / 230 V; variation −6% / +10% |
| Connections | 4 mm safety sockets for voltage/2-wire resistance and low-current ≤2 A |
| Dc Voltage Accuracy | 1-year total accuracy class ~50 ppm of setting + offset (range-dependent) |
| High Voltage Safety | Auto standby above 20 V / 200 V steps; ramped HV for auto-ranging DUTs |
| Platform | 3000A Series workstation calibrator with optional lead sets and scopes amplitude verification |
| Document | 3050A Extended Specifications V1.60 + 3000 Series Operation Manual V5.10 |
| Applications | Calibration laboratories and instrument workshops for DMM/process instruments |