Endress+Hauser
Endress+Hauser Thermophant T TTR35 Temperature Switch
Quote on request
No online payment · add lines to RFQ BOM
Hygienic Pt100 switch; −50…150 °C; PNP/4–20 mA; 3-A. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
−50 to 150 °C (−58 to 302 °F); −50 to 200 °C with extension neck
Output
1× PNP; 2× PNP; or PNP + active 4–20 mA
Supply
12 to 30 VDC
Process connection
Hygienic: conical metal-metal G½"; Clamp 1"–2" DIN 32676; Varivent F/N; DIN 11851; APV Inline
Wetted parts
Process connection AISI 316L
Ambient temperature
−40 to 85 °C
Fits hygienic temperature switching where you need a Thermophant T TTR35 Pt100 switch with PNP or PNP+4–20 mA outputs and 3-A documented wetted design.
Key advantages
- Range — −50 to 150 °C (−58 to 302 °F); to 200 °C with extension neck
- Sensor — Pt100 Class A (IEC 60751); FDA-compliant hygienic design
- Outputs — 1× PNP; 2× PNP; or PNP + active 4–20 mA
- Hygiene — 3-A mark; hygienic connections (Clamp, Varivent, DIN 11851, etc.)
- Response — t50 < 1.0 s; t90 < 2.0 s in flowing water (IEC 60751)
Typical applications
- Dairy, beverage, and hygienic process temperature switching.
- Compact sanitary points needing local display and PNP outputs.
- Loops that want switch plus active 4–20 mA from one device.
Selection guide
- Output — 1× PNP vs 2× PNP vs PNP + 4–20 mA
- Connection — Clamp / Varivent / DIN 11851 / conical metal-metal G½"
- Neck — Extension neck if process approaches 200 °C class
- Protection — IP65/IP66; IP69K optional with locking connector
Common mistakes
- Ordering without extension neck when process exceeds ~150 °C at the sensor.
- Assuming relay dry contacts — outputs are PNP (and optional mA).
- Skipping hygienic certificate needs on the RFQ.
When to RFQ / what to tell us
- Span, output configuration, hygienic connection.
- IP69K / neck options; supply 12–30 VDC.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 141132 |
| Brand | Endress+Hauser |
| Model | E+H Thermophant T TTR35 Temperature Switch |
| Product type | Temperature Switch |
| Measuring range | −50 to 150 °C (−58 to 302 °F); −50 to 200 °C with extension neck |
| Sensor | Pt100 RTD, Class A per IEC 60751; FDA-compliant hygienic design |
| Total error | ≤0.5 K (−50…75 °C); ≤0.75 K (75…200 °C) |
| Output | 1× PNP; 2× PNP; or PNP + active 4–20 mA |
| Supply | 12 to 30 VDC |
| Process connection | Hygienic: conical metal-metal G½"; Clamp 1"–2" DIN 32676; Varivent F/N; DIN 11851; APV Inline |
| Protection | IP65/IP66; IP69K optional with locking connector |
| Response time | t50 < 1.0 s; t90 < 2.0 s in flowing water per IEC 60751 |
| Hygiene | 3-A mark; materials in contact with food/product documented in TI |
| Wetted materials | Process connection AISI 316L |
Documents
FAQ
Q: What outputs are available? A: 1× PNP, 2× PNP, or PNP + active 4–20 mA.
Q: Is it hygienic? A: Yes — 3-A mark with hygienic process connections; see TI for materials.
Q: What should I send for a quote? A: Span/output/connection, options, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | −50 to 150 °C (−58 to 302 °F); −50 to 200 °C with extension neck |
| Output | 1× PNP; 2× PNP; or PNP + active 4–20 mA |
| Supply | 12 to 30 VDC |
| Process connection | Hygienic: conical metal-metal G½"; Clamp 1"–2" DIN 32676; Varivent F/N; DIN 11851; APV Inline |
| Wetted parts | Process connection AISI 316L |
| Ambient temperature | −40 to 85 °C |
| Display | Local digital display and LEDs |
| Sensor | Pt100 RTD, Class A per IEC 60751; FDA-compliant hygienic design |
| Accuracy Total Error | ≤0.5 K (−50…75 °C); ≤0.75 K (75…200 °C) |
| Degree Of Protection | IP65/IP66; IP69K optional with locking connector |
| Sensor Response Time | t50 < 1.0 s; t90 < 2.0 s in flowing water per IEC 60751 |
| Long Term Drift | ≤0.1 K/a |
| Hygiene Standard | 3-A mark; materials in contact with food/product documented in TI |
| Min Measuring Span | 20 K |