Rosemount

Rosemount 248H HART Temperature Transmitter

SKU · 38780 · 248H · Brand: Rosemount
Available
Quote on request
No online payment · add lines to RFQ BOM

248H: head-mount HART; Pt100 −200…850 °C; RTD/TC/ohm/mV; 4–20 mA. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
Pt100 (IEC 751) digital ±0.15 °C / D/A ±0.10% of span; enhanced accuracy option P8 ±0.1 °C digital
Output
2-wire 4–20 mA with HART digital (Rev 5 default; HR7 optional)
Supply
12.0 to 42.4 Vdc at terminals; load 250–1100 Ω; ≥17.75 Vdc with 250 Ω for HART
Ambient temperature
Standard −40 to +85 °C (−40 to +185 °F); cold options BR5/BR6 extend low end to −51/−60 °C; feature range −50 to +85 °C
Mounting
DIN B head mount (248H) with variety of enclosure options
Sensor Inputs
Single sensor; universal RTD, thermocouple, potentiometer, linear resistance, bipolar mV
Download datasheet PDF

Fits HART-capable head-mount temperature loops where you need a Rosemount 248H—4–20 mA with HART accepting Pt100 (−200…+850 °C) plus RTD, thermocouple, ohm, and mV inputs.

Key advantages

  • Inputs — Pt100 −200…+850 °C; RTD, T/C, ohm, mV
  • Output — 4–20 mA with HART
  • Form — Head-mount 248H
  • Use — Single-channel HART temperature
  • Platform — Rosemount 248 family

Typical applications

  • HART thermowell heads.
  • Commissionable RTD/TC loops.
  • Plant standard temperature points.

Selection guide

  • 248H vs 248R rail
  • Sensor type
  • HART handheld/tools

Common mistakes

  • Ordering 148 when HART required.
  • Wrong CJC awareness for TC.
  • Rail space needed but head ordered.

When to RFQ / what to tell us

  1. Sensor, range.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU38780
BrandRosemount
ModelRosemount 248H Temperature Transmitter
Product typeTemperature Transmitter
TypeHead-mount HART temperature transmitter (Rosemount 248H)
InputsPt100 −200…+850 °C; RTD, T/C, ohm, mV
Output4–20 mA with HART
FeatureHART-capable single-channel temperature transmitter

Documents

FAQ

Q: HART? A: Yes — 4–20 mA with HART.

Q: vs 248R? A: 248H is head-mount; 248R is rail-mount.

Q: What should I send for a quote? A: Sensor/range, quantity, ship-to.

Links

ParameterValue
AccuracyPt100 (IEC 751) digital ±0.15 °C / D/A ±0.10% of span; enhanced accuracy option P8 ±0.1 °C digital
Output2-wire 4–20 mA with HART digital (Rev 5 default; HR7 optional)
Supply12.0 to 42.4 Vdc at terminals; load 250–1100 Ω; ≥17.75 Vdc with 250 Ω for HART
Ambient temperatureStandard −40 to +85 °C (−40 to +185 °F); cold options BR5/BR6 extend low end to −51/−60 °C; feature range −50 to +85 °C
MountingDIN B head mount (248H) with variety of enclosure options
Sensor InputsSingle sensor; universal RTD, thermocouple, potentiometer, linear resistance, bipolar mV
StabilityRTD ±0.25% of reading or 0.25 °C (5 yr); RTD/TC option ±0.1% of reading or 0.1 °C (whichever greater)
IsolationInput/output isolation 500 Vac rms (707 Vdc); feature galvanic isolation 2.5 kVAC
Humidity0 to 95% RH non-condensing
Update Rate<0.5 s; turn-on <5 s (damping 0)
Damping0–32 s (default 5 s)
DiagnosticsOpen/short sensor diagnostics; NAMUR NE21/NE43; SIL 2 capable (option QT)