Image unavailable
Image unavailable
Rosemount
Rosemount 848T Eight-Input Temperature Transmitter
Quote on request
No online payment · add lines to RFQ BOM
848T: 8 inputs RTD/TC/mV/ohm; FOUNDATION Fieldbus. RFQ I/O.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Ambient temperature
−40 to +85 °C (−40 to +185 °F)
Inputs Ff
Eight independently configurable channels: 2-/3-wire RTD, thermocouple, mV, 2-/3-wire ohm; optional 4–20 mA
Protocol
FOUNDATION Fieldbus (IEC 61158) and WirelessHART variants
Accuracy Rtd Reference
±0.30 °C (±0.54 °F) Pt100 at 20 °C reference (FF)
Stability
±0.1% of reading or 0.1 °C (whichever greater) for 2 years RTDs / 1 year thermocouples
Update Time
Approximately 1.5 s to read all eight inputs (FF)
Fits multi-point temperature on FOUNDATION Fieldbus where you need a Rosemount 848T—up to eight RTD, thermocouple, mV, or ohm inputs (optional 4–20 mA) on a digital FF output.
Key advantages
- Inputs — 8× RTD, TC, mV, ohm; optional 4–20 mA
- Output — FOUNDATION Fieldbus digital
- Use — Multi-point temperature concentration
- Form — Multi-channel FF transmitter
- Platform — Rosemount 848T
Typical applications
- Multi-point reactor temperature.
- FF segment temperature clusters.
- Reduced home-run wiring.
Selection guide
- Input mix
- FF segment plan
- Enclosure / DIN options
Common mistakes
- Expecting 4–20 mA primary output.
- Under-counting channels.
- Wrong TC type configuration.
When to RFQ / what to tell us
- Input map, options.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 38782 |
| Brand | Rosemount |
| Model | Rosemount 848T Temperature Transmitter |
| Product type | Temperature Transmitter |
| Type | Eight-input FOUNDATION Fieldbus temperature transmitter (Rosemount 848T) |
| Inputs | 8× RTD, TC, mV, ohm; optional 4–20 mA |
| Output | FOUNDATION Fieldbus digital |
| Feature | Multi-input FF temperature transmitter |
Documents
FAQ
Q: How many inputs? A: Eight measurement inputs.
Q: Protocol? A: FOUNDATION Fieldbus.
Q: What should I send for a quote? A: Input map/quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Ambient temperature | −40 to +85 °C (−40 to +185 °F) |
| Inputs Ff | Eight independently configurable channels: 2-/3-wire RTD, thermocouple, mV, 2-/3-wire ohm; optional 4–20 mA |
| Protocol | FOUNDATION Fieldbus (IEC 61158) and WirelessHART variants |
| Accuracy Rtd Reference | ±0.30 °C (±0.54 °F) Pt100 at 20 °C reference (FF) |
| Stability | ±0.1% of reading or 0.1 °C (whichever greater) for 2 years RTDs / 1 year thermocouples |
| Update Time | Approximately 1.5 s to read all eight inputs (FF) |
| Supply Voltage Ff | 9.0 to 32.0 VDC over FOUNDATION Fieldbus; 22 mA max |
| Humidity | 0–99% RH non-condensing |
| Isolation | 600 VDC channel-to-channel (ref conditions); 10 VDC all operating conditions with ≤500 ft sensor leads |
| Emc | EN 61326 and NAMUR NE-21 industrial environment; max deviation <1% span during disturbance |
| Diagnostics | Measurement validation diagnostic for sensor degradation, wiring, vibration, abnormal process |
| Function Blocks Ff | AI, MAI, ISEL; Backup Link Active Scheduler |
| Enclosure | Options for mounting close to process including hazardous areas / intrinsically safe design |
| Turn On Time | <30 s to within specifications after power applied |