Rosemount

Rosemount 848T Eight-Input Temperature Transmitter

SKU · 38782 · 848T Temperature Transmitter · Brand: Rosemount
Available
Quote on request
No online payment · add lines to RFQ BOM

848T: 8 inputs RTD/TC/mV/ohm; FOUNDATION Fieldbus. RFQ I/O.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Ambient temperature
−40 to +85 °C (−40 to +185 °F)
Inputs Ff
Eight independently configurable channels: 2-/3-wire RTD, thermocouple, mV, 2-/3-wire ohm; optional 4–20 mA
Protocol
FOUNDATION Fieldbus (IEC 61158) and WirelessHART variants
Accuracy Rtd Reference
±0.30 °C (±0.54 °F) Pt100 at 20 °C reference (FF)
Stability
±0.1% of reading or 0.1 °C (whichever greater) for 2 years RTDs / 1 year thermocouples
Update Time
Approximately 1.5 s to read all eight inputs (FF)
Download datasheet PDF

Fits multi-point temperature on FOUNDATION Fieldbus where you need a Rosemount 848T—up to eight RTD, thermocouple, mV, or ohm inputs (optional 4–20 mA) on a digital FF output.

Key advantages

  • Inputs — 8× RTD, TC, mV, ohm; optional 4–20 mA
  • Output — FOUNDATION Fieldbus digital
  • Use — Multi-point temperature concentration
  • Form — Multi-channel FF transmitter
  • Platform — Rosemount 848T

Typical applications

  • Multi-point reactor temperature.
  • FF segment temperature clusters.
  • Reduced home-run wiring.

Selection guide

  • Input mix
  • FF segment plan
  • Enclosure / DIN options

Common mistakes

  • Expecting 4–20 mA primary output.
  • Under-counting channels.
  • Wrong TC type configuration.

When to RFQ / what to tell us

  1. Input map, options.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU38782
BrandRosemount
ModelRosemount 848T Temperature Transmitter
Product typeTemperature Transmitter
TypeEight-input FOUNDATION Fieldbus temperature transmitter (Rosemount 848T)
Inputs8× RTD, TC, mV, ohm; optional 4–20 mA
OutputFOUNDATION Fieldbus digital
FeatureMulti-input FF temperature transmitter

Documents

FAQ

Q: How many inputs? A: Eight measurement inputs.

Q: Protocol? A: FOUNDATION Fieldbus.

Q: What should I send for a quote? A: Input map/quantity, ship-to.

Links

ParameterValue
Ambient temperature−40 to +85 °C (−40 to +185 °F)
Inputs FfEight independently configurable channels: 2-/3-wire RTD, thermocouple, mV, 2-/3-wire ohm; optional 4–20 mA
ProtocolFOUNDATION Fieldbus (IEC 61158) and WirelessHART variants
Accuracy Rtd Reference±0.30 °C (±0.54 °F) Pt100 at 20 °C reference (FF)
Stability±0.1% of reading or 0.1 °C (whichever greater) for 2 years RTDs / 1 year thermocouples
Update TimeApproximately 1.5 s to read all eight inputs (FF)
Supply Voltage Ff9.0 to 32.0 VDC over FOUNDATION Fieldbus; 22 mA max
Humidity0–99% RH non-condensing
Isolation600 VDC channel-to-channel (ref conditions); 10 VDC all operating conditions with ≤500 ft sensor leads
EmcEN 61326 and NAMUR NE-21 industrial environment; max deviation <1% span during disturbance
DiagnosticsMeasurement validation diagnostic for sensor degradation, wiring, vibration, abnormal process
Function Blocks FfAI, MAI, ISEL; Backup Link Active Scheduler
EnclosureOptions for mounting close to process including hazardous areas / intrinsically safe design
Turn On Time<30 s to within specifications after power applied