Rosemount

Rosemount 214C Thermocouple Temperature Sensor

SKU · 43519 · 214C Thermocouple · Brand: Rosemount
Available
Quote on request
No online payment · add lines to RFQ BOM

Rosemount 214C TC: Types E/J/K/N/T; −196…1200 °C class; MI cable. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Type-dependent: E −40…+900 °C; J −40…+760 °C; K/N −40…+1200 °C; T −196…+370 °C (family −196 to +1200 °C)
Accuracy
Class 1 or Class 2 per IEC 60584; Special Tolerances per ASTM E230 (order option)
Approvals
Global hazardous-location product approvals by option code
Mounting
Spring-loaded and compact spring-loaded styles; compression fittings / welded adapters
Sensor Types
Thermocouple Types E, J, K, N, T (IEC/ASTM)
Sheath Diameter
¼ in (6 mm) nominal MI cable standard
Download datasheet PDF

Fits process thermocouple sensing where you need a Rosemount 214C—thermocouple sensor in Types E, J, K, N or T with type-dependent spans from about −196 to +1200 °C, Class 1/2 or ASTM special tolerances, ¼ in MI cable standard, and single/dual grounded or ungrounded junctions.

Key advantages

  • Types — E, J, K, N, T (IEC/ASTM)
  • Span — Type-dependent; family about −196 to +1200 °C
  • Accuracy — Class 1/2 IEC 60584 or ASTM special tolerances
  • Sheath — ¼ in (6 mm) nominal MI cable standard
  • Config — Single/dual; grounded/ungrounded

Typical applications

  • Process temperature points.
  • Thermowell assemblies.
  • Transmitter-matched TCs.

Selection guide

  • Type letter
  • Junction / dual
  • Sheath / mounting

Common mistakes

  • Wrong type for temperature.
  • Grounded junction noise.
  • Ignoring immersion rules.

When to RFQ / what to tell us

  1. Type/sheath/mount codes.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU43519
BrandRosemount
Model214C Thermocouple
Product typeThermocouple Temperature Sensor
Sensor typesThermocouple Types E, J, K, N, T (IEC/ASTM)
Measuring rangeType-dependent: E −40…+900 °C; J −40…+760 °C; K/N −40…+1200 °C; T −196…+370 °C (family −196 to +1200 °C)
AccuracyClass 1 or Class 2 per IEC 60584; Special Tolerances per ASTM E230 (order option)
Sheath diameter¼ in (6 mm) nominal MI cable standard
Sheath materialStandard sheath materials defined by sensor type (PDS )
Element configurationSingle or dual; grounded or ungrounded junctions
MountingSpring-loaded and compact spring-loaded styles; compression fittings / welded adapters
Lead wires24 AWG FEP-insulated, color-coded per IEC 60584 or ASTM E230

Documents

FAQ

Q: Types? A: E, J, K, N, T.

Q: Sheath? A: ¼ in (6 mm) MI cable standard.

Q: What should I send for a quote? A: Type/sheath/mount, quantity, ship-to.

Links

ParameterValue
Measuring rangeType-dependent: E −40…+900 °C; J −40…+760 °C; K/N −40…+1200 °C; T −196…+370 °C (family −196 to +1200 °C)
AccuracyClass 1 or Class 2 per IEC 60584; Special Tolerances per ASTM E230 (order option)
ApprovalsGlobal hazardous-location product approvals by option code
MountingSpring-loaded and compact spring-loaded styles; compression fittings / welded adapters
Sensor TypesThermocouple Types E, J, K, N, T (IEC/ASTM)
Sheath Diameter¼ in (6 mm) nominal MI cable standard
Sheath MaterialStandard sheath materials defined by sensor type (PDS Table 3)
Element ConfigurationSingle or dual; grounded or ungrounded junctions
Lead Wires24 AWG FEP-insulated, color-coded per IEC 60584 or ASTM E230
Insulation Resistance1000 MΩ minimum at 500 VDC at room temperature
VibrationEngineered for high-vibration industrial service
Form FactorSensor-only or Complete Point Solution with transmitter/thermowell assembly
CalibrationCalibration services / certificate options available