Aalborg

Aalborg GFC Mass Flow Controller

SKU · 10207 · GFC Mass Flow Controllers · Brand: Aalborg
Available
Quote on request
No online payment · add lines to RFQ BOM

Thermal MFC. ~10 mL/min–1000 L/min N2; ±1% FS class. RFQ + engineer selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
Typical +/-1.0% FS (0-100% on GFC 17/37/47 class); enhanced options on larger models
Display
Built-in tiltable LCD readout (removable for remote)
Type
Thermal mass flow controller family (GFC)
Flow Ranges
About 10 mL/min to 1000 L/min N2 (model dependent)
Repeatability
+/-0.5% of full scale
Response
GFC17 ~1 s to +/-2% of set flow; larger models slower (model dependent)
Download datasheet PDF

Fits clean-gas dosing where you need an Aalborg GFC thermal mass flow controller with local/remote setpoint and NC valve.

Key advantages

  • Thermal MFC — Thermal mass flow controller family (GFC)
  • Ranges — About 10 mL/min to 1000 L/min N2 (model dependent)
  • Accuracy / repeatability — Typical +/-1.0% FS (0-100% on GFC 17/37/47 class); enhanced options on larger models; +/-0.5% of full scale
  • Response — GFC17 ~1 s to +/-2% of set flow; larger models slower (model dependent)
  • I/O — 0-5 Vdc and 4-20 mA; local/remote setpoint; normally-closed valve; tiltable LCD.

Typical applications

  • Gas blending and dosing panels needing closed-loop mass-flow control.
  • Lab and OEM tools with 0–5 V / 4–20 mA setpoint and feedback.
  • Installations wanting a removable tiltable LCD on the controller.

Selection guide

  • Range / model — About 10 mL/min to 1000 L/min N2 (model dependent)
  • Accuracy — Typical +/-1.0% FS (0-100% on GFC 17/37/47 class); enhanced options on larger models
  • Max pressure — 1000 psig (70 bar)
  • Setpoint mode — local vs remote; valve normally-closed.
  • Leak integrity — 1e-9 smL/sec He

Common mistakes

  • Ordering a meter (GFM) when the loop needs active control (GFC).
  • Expecting GFC17 ~1 s response on larger models — response is model-dependent.
  • Skipping elastomer/material compatibility for the process gas.

When to RFQ / what to tell us

  1. Gas, calibrated range, inlet/outlet pressure.
  2. Setpoint interface (0–5 V / 4–20 mA); materials; LCD; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU10207
BrandAalborg
ModelGFC Mass Flow Controllers
Product typeMass Flow Controller
TypeThermal mass flow controller family (GFC)
Flow rangesAbout 10 mL/min to 1000 L/min N2 (model dependent)
AccuracyTypical +/-1.0% FS (0-100% on GFC 17/37/47 class); enhanced options on larger models
Repeatability+/-0.5% of full scale
ResponseGFC17 ~1 s to +/-2% of set flow; larger models slower (model dependent)
Max pressure1000 psig (70 bar)
Leak integrity1e-9 smL/sec He
Outputs0-5 Vdc and 4-20 mA; local/remote setpoint; normally-closed valve
DisplayBuilt-in tiltable LCD readout (removable for remote)

Documents

FAQ

Q: GFM vs GFC? A: GFM measures; GFC controls with a normally-closed valve and setpoint input.

Q: Accuracy? A: Typical ±1.0% FS on GFC 17/37/47 class; enhanced options on larger models.

Q: What should I send for a quote? A: Gas, range, P, I/O, materials, quantity.

Links

ParameterValue
AccuracyTypical +/-1.0% FS (0-100% on GFC 17/37/47 class); enhanced options on larger models
DisplayBuilt-in tiltable LCD readout (removable for remote)
TypeThermal mass flow controller family (GFC)
Flow RangesAbout 10 mL/min to 1000 L/min N2 (model dependent)
Repeatability+/-0.5% of full scale
ResponseGFC17 ~1 s to +/-2% of set flow; larger models slower (model dependent)
Max Pressure1000 psig (70 bar)
Leak Integrity1e-9 smL/sec He
Outputs0-5 Vdc and 4-20 mA; local/remote setpoint; normally-closed valve
DocumentAalborg GFC catalog EM20250925