E+E Elektronik

E+E EE741 Inline Flow Meter

SKU · 43369 · E+E EE741 Inline Flow Meter · Brand: E+E Elektronik
Available
Quote on request
No online payment · add lines to RFQ BOM

E+E EE741: inline thermal flow meter; compressed air/gases; pipe sizes/outputs. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
+/-(3% of measured value + 0.3% of full scale) in air at 7 bar abs / 23 C
Type
Inline thermal mass flow sensor for compressed air and gases (EE741)
Pipe Sizes
DN15 to DN50 (1/2 in to 2 in) via gauge mounting blocks
Media
Compressed air and technical gases such as O2, N2, Ar, CO2
Flow Ranges
About 0.2-76.3 m3/h (DN15) up to 2.2-848.2 m3/h (DN50) at standard conditions
Response
t90 < 2 s; sampling interval 0.1 s
Download datasheet PDF

Fits compressed-air and gas flow metering where you need an E+E Elektronik EE741—inline thermal flow meter with selectable pipe sizes, media-specific flow ranges, and analogue/digital outputs per OEM configuration.

Key advantages

  • Type — Inline thermal mass flow meter
  • Media — Compressed air and process gases (per OEM)
  • Pipe sizes — Selectable per EE741 matrix
  • Outputs — Analogue/digital per config
  • Platform — E+E EE741

Typical applications

  • Compressed-air consumption.
  • Nitrogen / process gas lines.
  • Energy monitoring on utilities.

Selection guide

  • Pipe size / DN
  • Gas type
  • Output / display

Common mistakes

  • Wrong pipe ID.
  • Condensate without prep.
  • Ignoring upstream straight-run.

When to RFQ / what to tell us

  1. DN/gas/output.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU43369
BrandE+E Elektronik
ModelE+E EE741 Inline Flow Meter
Product typeInline Flow Meter
TypeInline thermal mass flow sensor for compressed air and gases (EE741)
Pipe sizesDN15 to DN50 (1/2 in to 2 in) via gauge mounting blocks
MediaCompressed air and technical gases such as O2, N2, Ar, CO2
Flow rangesAbout 0.2-76.3 m3/h (DN15) up to 2.2-848.2 m3/h (DN50) at standard conditions
Accuracy+/-(3% of measured value + 0.3% of full scale) in air at 7 bar abs / 23 C
TemperatureMedium -20 to +60 C; temperature accuracy about +/-0.7 C
Outputs0-20 / 4-20 mA; switch; pulse; Modbus RTU; M-Bus; IO-Link options

Documents

FAQ

Q: Media? A: Compressed air and gases per OEM list.

Q: Form? A: Inline thermal flow meter.

Q: What should I send for a quote? A: DN/gas/output, quantity, ship-to.

Links

ParameterValue
Accuracy+/-(3% of measured value + 0.3% of full scale) in air at 7 bar abs / 23 C
TypeInline thermal mass flow sensor for compressed air and gases (EE741)
Pipe SizesDN15 to DN50 (1/2 in to 2 in) via gauge mounting blocks
MediaCompressed air and technical gases such as O2, N2, Ar, CO2
Flow RangesAbout 0.2-76.3 m3/h (DN15) up to 2.2-848.2 m3/h (DN50) at standard conditions
Responset90 < 2 s; sampling interval 0.1 s
TemperatureMedium -20 to +60 C; temperature accuracy about +/-0.7 C
Outputs0-20 / 4-20 mA; switch; pulse; Modbus RTU; M-Bus; IO-Link options
PrincipleThermal hot-film sensing; modular sensing unit removable without pipework teardown
DocumentE+E datasheet_EE741.pdf