Key parameters

Measuring range
20 to 733501 kg/h (44 to 1669340 lb/h) gas/size dependent
Accuracy
Gas ±1.0% o.r. (10–100% o.f.s.); ±0.1% o.f.s. (1–10% o.f.s.)
Output
Remote Proline 500 transmitter; up to 4 I/Os; HART / Modbus RS485 and other fieldbuses
Wetted parts
Insertion tube stainless 1.4404 (316/316L); process connections G/NPT compression fittings
Protection
IP66/67 Type 4X; optional IP68 Type 6P (Proline 500)
Ambient temperature
−40 to +60 °C (−40 to +140 °F); optional colder ratings
Download datasheet PDF

Fits large-line insertion gas mass flow where you need an Endress+Hauser Proline t-mass I 500. Thermal mass insertion sensor for gases and mixtures in pipes or ducts DN 80 to 1500 (3 to 60 in), gas accuracy ±1.0% of reading (10–100% o.f.s.) and ±0.1% o.f.s. (1–10%), with bidirectional and reverse-flow detection options and Gas Engine gas handling.

Key advantages

  • Line size — Insertion DN 80–1500 (3–60 in)
  • Accuracy — ±1.0% o.r. (10–100% o.f.s.)
  • Principle — Thermal mass; Gas Engine
  • Bidirectional — Reverse-flow options
  • Range — Gas/size dependent to 733501 kg/h class

Typical applications

  • Large duct gas flow.
  • Utility / process gas insertion.
  • Bidirectional gas monitoring.

Selection guide

  • DN / insertion length
  • Gas set
  • Bidirectional need

Common mistakes

  • Undersized insertion.
  • Wrong gas mix.
  • Ignoring reverse-flow option.

When to RFQ / what to tell us

  1. DN/gas/options.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU48023
BrandEndress+Hauser
ModelProline t-mass I 500
Product typeThermal Mass Flow Meter
Measuring principleThermal mass insertion sensor for gases/mixtures in pipes or ducts; Gas Engine
Line sizeInsertion DN 80 to 1500 (3 to 60 in)
Measuring range20 to 733501 kg/h (44 to 1669340 lb/h) gas/size dependent
AccuracyGas ±1.0% o.r. (10–100% o.f.s.); ±0.1% o.f.s. (1–10% o.f.s.)
BidirectionalYes with reverse-flow detection options

Documents

FAQ

Q: DN range? A: 80 to 1500 (3 to 60 in).

Q: Bidirectional? A: Yes with reverse-flow options.

Q: What should I send for a quote? A: DN/gas/options, quantity, ship-to.

Links

ParameterValue
Measuring range20 to 733501 kg/h (44 to 1669340 lb/h) gas/size dependent
AccuracyGas ±1.0% o.r. (10–100% o.f.s.); ±0.1% o.f.s. (1–10% o.f.s.)
OutputRemote Proline 500 transmitter; up to 4 I/Os; HART / Modbus RS485 and other fieldbuses
Wetted partsInsertion tube stainless 1.4404 (316/316L); process connections G/NPT compression fittings
ProtectionIP66/67 Type 4X; optional IP68 Type 6P (Proline 500)
Ambient temperature−40 to +60 °C (−40 to +140 °F); optional colder ratings
DisplayBacklit touch control with WLAN access
Measuring PrincipleThermal mass insertion sensor for gases/mixtures in pipes or ducts; Gas Engine
Line SizeInsertion DN 80 to 1500 (3 to 60 in)
BidirectionalYes with reverse-flow detection options
Medium TemperatureSensor −40 to +180 °C (−40 to +356 °F); FKM / 1.4404 seal options same range
Medium Pressure−0.5 to 20 bar_g (−7.25 to 290 psi_g); max extraction pressure 16 bar typical
Special FeaturesHeartbeat Technology; SIL 2 sensor option; remote transmitter architecture