Extech

Extech PRC20 Thermocouple Calibrator

SKU · 39094 · PRC20 Thermocouple Calibrator · Brand: Extech
Available
Quote on request
No online payment · add lines to RFQ BOM

PRC20: source/measure J/K/T/E/C/R/S/N; 0.05%±1°; CJC; presets. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Display
Dot-matrix backlit LCD with thermocouple type indication
Thermocouple Types
J, K, T, E, C, R, S, N (source and measure)
Type K Range
−50 to 1370 °C (−58 to 2498 °F)
Type J Range
−50 to 1000 °C (−58 to 1832 °F)
Type T Range
−120 to 400 °C (−184 to 752 °F)
Voltage Range
−10.00 mV to +60.00 mV; resolution 10 μV
Download datasheet PDF

Fits portable thermocouple source and measure work where you need an Extech PRC20—supports J, K, T, E, C, R, S, and N with cold-junction compensation, about 0.05% of reading ±1 °C class accuracy, and five adjustable presets.

Key advantages

  • Types — J, K, T, E, C, R, S, N
  • Ranges — e.g. K −50…1370 °C; J −50…1000 °C; T −120…400 °C class
  • Accuracy — About 0.05% of reading ±1 °C
  • mV — −10…+60 mV; CJC; five presets
  • Form — Pocket calibrator ~159×80×44 mm

Typical applications

  • TC loop simulation.
  • Panel temperature input checks.
  • Field transmitter source/measure.

Selection guide

  • NIST option
  • Spare TC leads
  • °C vs °F display

Common mistakes

  • Wrong TC type selected.
  • Missing CJC awareness.
  • Using beyond mV/TC ratings.

When to RFQ / what to tell us

  1. NIST option, quantity.
  2. Ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU39094
BrandExtech
ModelPRC20
Product typeThermocouple Calibrator
TypePortable thermocouple source/measure calibrator (Extech PRC20)
TypesJ, K, T, E, C, R, S, N
RangesK −50…1370 °C; J −50…1000 °C; T −120…400 °C; E −50…750 °C; C/R/S 0…1750 °C; N −50…1300 °C class
AccuracyAbout 0.05% of reading ±1 °C class
Mv−10…+60 mV; CJC; five presets
FormAbout 159×80×44 mm; ~225 g without batteries

Documents

FAQ

Q: Supported TC? A: J, K, T, E, C, R, S, N.

Q: Accuracy class? A: About 0.05% of reading ±1 °C.

Q: What should I send for a quote? A: Options/quantity, ship-to.

Links

ParameterValue
DisplayDot-matrix backlit LCD with thermocouple type indication
Thermocouple TypesJ, K, T, E, C, R, S, N (source and measure)
Type K Range−50 to 1370 °C (−58 to 2498 °F)
Type J Range−50 to 1000 °C (−58 to 1832 °F)
Type T Range−120 to 400 °C (−184 to 752 °F)
Voltage Range−10.00 mV to +60.00 mV; resolution 10 μV
Basic Accuracy0.05% of reading ±1° (temperature); 10 μV ±1 digit (mV)
Resolution0.1° up to 999.9° or 1° over 999.9° (J/K/T/E); 1° (R/N); 0.5° (C/S)
Input Impedance10 MΩ
Sampling Rate4 times/second
Dimensions159 × 80 × 44 mm (6.3 × 3.2 × 1.7 in)
Weight225 g (8 oz) without batteries
Power6 × AA (1.5 V) or external 100–240 V AC adaptor
CertificationsCE