Endress+Hauser

Endress+Hauser T13 Explosion-Proof Pt100 RTD Thermometer

SKU · 47787 · T13 Pt100 Explosion Proof Thermometer · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H T13: Ex Pt100; TF −50…200 °C / WW −200…600 °C; Class A/B; to 100 bar. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
TF −50 to 200 °C; WW −200 to 600 °C; StrongSens −50 to 500 °C
Accuracy
Class A or Class B per IEC 60751 (configuration dependent)
Wetted parts
316L SS, Hastelloy C276 and other barstock options
Approvals
FM/CSA XP Class I Div. 1; CSA C/US XP
Measuring Principle
Pt100 RTD per IEC 60751 (thin-film or wire-wound; StrongSens options)
Response Time
Typically 63% response ≈ 20 s (configuration dependent)
Download datasheet PDF

Fits explosion-proof RTD temperature where you need an Endress+Hauser T13. Pt100 thermometer per IEC 60751 with thin-film −50 to 200 °C, wire-wound −200 to 600 °C or StrongSens −50 to 500 °C options, Class A or B accuracy, process pressure to 100 bar at 20 °C depending on thermowell, and immersion lengths to about 22.5 in (571 mm).

Key advantages

  • Principle — Pt100 IEC 60751
  • Ranges — TF / WW / StrongSens options
  • Accuracy — Class A or B
  • Pressure — Up to 100 bar @ 20 °C (thermowell)
  • Immersion — Up to 22.5 in (571 mm)

Typical applications

  • Ex-area temperature.
  • Process RTD points.
  • Thermowell assemblies.

Selection guide

  • TF vs WW vs StrongSens
  • Class A/B
  • Thermowell / connection

Common mistakes

  • Wrong sensor construction.
  • Exceeding immersion.
  • Ignoring Ex approvals needed.

When to RFQ / what to tell us

  1. Construction/immersion/approvals.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47787
BrandEndress+Hauser
ModelT13 Pt100 Explosion Proof Thermometer
Product typeRTD Thermometer
Measuring principlePt100 RTD per IEC 60751 (thin-film or wire-wound; StrongSens options)
Measuring rangeTF −50 to 200 °C; WW −200 to 600 °C; StrongSens −50 to 500 °C
AccuracyClass A or Class B per IEC 60751 (configuration dependent)
Response timeTypically 63% response ≈ 20 s (configuration dependent)
Process pressureUp to 100 bar (1450 psi) at 20 °C (depends on thermowell/process connection)
Max immersionUp to 22.5 in (571 mm); others on request

Documents

FAQ

Q: WW range? A: −200 to 600 °C.

Q: Accuracy? A: Class A or B.

Q: What should I send for a quote? A: Construction/immersion/approvals, quantity, ship-to.

Links

ParameterValue
Measuring rangeTF −50 to 200 °C; WW −200 to 600 °C; StrongSens −50 to 500 °C
AccuracyClass A or Class B per IEC 60751 (configuration dependent)
Wetted parts316L SS, Hastelloy C276 and other barstock options
ApprovalsFM/CSA XP Class I Div. 1; CSA C/US XP
Measuring PrinciplePt100 RTD per IEC 60751 (thin-film or wire-wound; StrongSens options)
Response TimeTypically 63% response ≈ 20 s (configuration dependent)
Process PressureUp to 100 bar (1450 psi) at 20 °C (depends on thermowell/process connection)
Max ImmersionUp to 22.5 in (571 mm); others on request
Protection ClassIP66/67
Transmitter StabilityiTEMP long-term stability ≤ 0.05% per year
ConstructionBarstock thermowell + spring-loaded insert + explosion-proof head
ApplicationsChemicals, petrochemical, refineries, offshore platforms
Special FeaturesSingle model number covers sensor + thermowell + transmitter complete point solution