Watlow

Watlow Pipe Clamp Thermocouple

SKU · 22620 · Pipe Clamp Thermocouple · Brand: Watlow
Available
Quote on request
No online payment · add lines to RFQ BOM

Style 72 pipe clamp TC; no drill/tap; bands to 7 in. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Fiberglass leads continuous to 480 °C (900 °F); PFA typically to 260 °C (500 °F)
Accuracy
Standard ASTM E230 thermocouple tolerances (type/temperature dependent)
Mounting
Stainless steel clamp; no drilling or tapping required
Sensor type
Thermocouple types J, K, T, E; grounded junction
Construction Style
Style 72 pipe clamp thermocouple
Clamp Band Ranges
A 11/16–1¼; B 1¼–2¼; C 2¼–3¼; D 3¼–4¼; E 4¼–5; F 5–6; G 6–7 in
Download datasheet PDF

Fits pipe surface temperature without drilling where you need a Watlow Style 72 pipe clamp thermocouple with stainless clamp bands covering about 11/16 in to 7 in OD.

Key advantages

  • Style — Style 72 pipe clamp thermocouple
  • Types — J, K, T, E; grounded junction
  • Clamp bands — A–G covering ~11/16 in to 7 in pipe OD
  • Temperature — Fiberglass to 480 °C (900 °F); PFA to 260 °C (500 °F)
  • Mounting — Stainless clamp; no drilling or tapping

Typical applications

  • Pipe surface and heat-trace monitoring.
  • Process tracing lines.
  • Industrial heat systems without penetration.

Selection guide

  • Band size — Match pipe OD (A–G)
  • Calibration — J/K/T/E
  • Lead protection — Fiberglass/PFA + SS braid
  • Terminations — Plugs, spades, BX

Common mistakes

  • Wrong band for pipe OD.
  • Expecting immersion accuracy from surface clamp.
  • Exceeding lead insulation rating.

When to RFQ / what to tell us

  1. Pipe OD, type, lead length.
  2. Terminations; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU22620
BrandWatlow
ModelPipe Clamp Thermocouple
Product typeThermocouple
ConstructionStyle 72 pipe clamp thermocouple
Sensor typeThermocouple types J, K, T, E; grounded junction
Measuring rangeFiberglass leads continuous to 480 °C (900 °F); PFA typically to 260 °C (500 °F)
Clamp band rangesA 11/16–1¼; B 1¼–2¼; C 2¼–3¼; D 3¼–4¼; E 4¼–5; F 5–6; G 6–7 in
Lead protectionFiberglass or PFA with stainless steel overbraid (20 or 24 gauge stranded)
Lead length6 to 360 in (over 360 in contact factory)
MountingStainless steel clamp; no drilling or tapping required
TerminationsSplit leads, #6 spade lugs, BX, standard/miniature plugs/jacks, ¼ in push-on
AccuracyStandard ASTM E230 thermocouple tolerances (type/temperature dependent)
ApplicationsPipe surface temperature; process tracing; industrial heat systems
FeaturesIdeal for measuring pipe temperatures without process penetration

Documents

FAQ

Q: Need to drill the pipe? A: No — stainless clamp mounts without drilling or tapping.

Q: Band sizes? A: Seven ranges from about 11/16 in to 7 in.

Q: What should I send for a quote? A: Pipe OD/type/leads, quantity, ship-to.

Links

ParameterValue
Measuring rangeFiberglass leads continuous to 480 °C (900 °F); PFA typically to 260 °C (500 °F)
AccuracyStandard ASTM E230 thermocouple tolerances (type/temperature dependent)
MountingStainless steel clamp; no drilling or tapping required
Sensor typeThermocouple types J, K, T, E; grounded junction
Construction StyleStyle 72 pipe clamp thermocouple
Clamp Band RangesA 11/16–1¼; B 1¼–2¼; C 2¼–3¼; D 3¼–4¼; E 4¼–5; F 5–6; G 6–7 in
Lead ProtectionFiberglass or PFA with stainless steel overbraid (20 or 24 gauge stranded)
Lead Length6 to 360 in (over 360 in contact factory)
TerminationsSplit leads, #6 spade lugs, BX, standard/miniature plugs/jacks, ¼ in push-on
ApplicationsPipe surface temperature; process tracing; industrial heat systems
Special FeaturesIdeal for measuring pipe temperatures without process penetration
Catalog FamilyWatlow general applications tube-and-wire thermocouples