C801: 4–20 mA Tuff Tilt; ±0.5/3/50°; IP65; loop-powered. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Output
4–20 mA two-wire current loop per axis
Supply
(0.02 A × R + 10 VDC) < Vs < 29 VDC; input current 25 mA
Angular Range
±0.5° (high-gain), ±3° (standard), or ±50° (wide-angle); custom ranges on request
Resolution
0.0001° / 0.0006° / 0.01° by range
Nonrepeatability
0.0002° / 0.001° / 0.02° max by range
Nonlinearity
1% / 2% / 0.5% FRO max by range
Fits long-cable tilt loops where you need a Jewell C801 Tuff Tilt 420—IP65 4–20 mA two-wire tiltmeter with ±0.5°/±3°/±50° ranges (uni or biaxial) and an onboard temperature channel.
Key advantages
- Output — 4–20 mA two-wire per axis
- Ranges — HG ±0.5°; Std ±3°; WA ±50°
- Resolution — <0.0001° / 0.0006° / 0.01°
- Seal — IP65; temperature channel
- Power — Loop-powered ~10–29 VDC class
Typical applications
- PLC 4–20 mA tilt inputs.
- Long-cable structural tilt.
- Industrial outdoor monitoring.
Selection guide
- Uni vs biaxial
- Gain
- Cable length
Common mistakes
- Using voltage input on PLC.
- Exceeding load impedance.
- Wrong gain for expected tilt.
When to RFQ / what to tell us
- Axes, gain.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 39645 |
| Brand | Jewell Instruments |
| Model | C801 Tuff Tilt 420 |
| Product type | Tiltmeter |
| Type | IP65 4–20 mA Tuff Tilt tiltmeter (C801) |
| Ranges | HG ±0.5°; Std ±3°; WA ±50°; uni or biaxial |
| Resolution | <0.0001° / 0.0006° / 0.01° |
| Output | 4–20 mA two-wire per axis; temperature channel |
| Power | Loop-powered ~10–29 VDC class; IP65 |
Documents
FAQ
Q: Output? A: 4–20 mA two-wire per axis.
Q: IP rating? A: IP65.
Q: What should I send for a quote? A: Axes/gain, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Output | 4–20 mA two-wire current loop per axis |
| Supply | (0.02 A × R + 10 VDC) < Vs < 29 VDC; input current 25 mA |
| Angular Range | ±0.5° (high-gain), ±3° (standard), or ±50° (wide-angle); custom ranges on request |
| Resolution | 0.0001° / 0.0006° / 0.01° by range |
| Nonrepeatability | 0.0002° / 0.001° / 0.02° max by range |
| Nonlinearity | 1% / 2% / 0.5% FRO max by range |
| Scale Factor | 0.0625°/mA / 0.375°/mA / 6.25°/mA (single-ended) by range |
| Axes | 1 (uniaxial) or 2 (biaxial) |
| Temperature Channel | 10 kΩ thermistor; −50 to +150 °C measurement span |
| Time Constant | 0.15 s |
| Operating Temperature | −40 to +85 °C |
| Enclosure | Diecast painted aluminum; IP65; ~120 × 80 × 60 mm; 0.5–0.6 kg |
| Cable | 3 m (10 ft) multi-conductor + overall shield, PVC jacket |