Rosemount

Rosemount T1056 Clarity II Turbidimeter

SKU · 31292 · Model T1056 Clarity II Turbidimeter · Brand: Rosemount
Available
Quote on request
No online payment · add lines to RFQ BOM

Clarity II; 0–200 NTU; 0.001 NTU; EPA/ISO sensors. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
After cal at 20.0 NTU: 0–1 NTU ±2% of reading or ±0.015 NTU (whichever greater); 0–20 NTU ±2% of reading
Wetted parts
Delrin, glass, EPDM (sensor/chamber)
Ambient temperature
32 to 131 °F (0 to 55 °C); turbidity-only 32 to 122 °F (0 to 50 °C); RH 5–95% non-condensing
Measurement Range
0 to 200 NTU class (display resolution 0.001 NTU; accuracy stated after 20.0 NTU calibration for 0–1 and 0–20 NTU bands)
Resolution
0.001 NTU (four-digit display; decimal shifts across 0.001–1000 class ranges)
Sensor Methods
US EPA 180.1 (incandescent) or ISO 7027 (860 nm LED); specified at order
Download datasheet PDF

Fits drinking-water and process turbidity monitoring where you need a Rosemount T1056 Clarity II system covering 0–200 NTU with 0.001 NTU resolution and EPA 180.1 or ISO 7027 sensor options.

Key advantages

  • Range / resolution — 0–200 NTU; 0.001 NTU display
  • Accuracy — After 20 NTU cal: 0–1 NTU ±2% or ±0.015 NTU; 0–20 NTU ±2%
  • Sensors — US EPA 180.1 or ISO 7027 compliant options
  • Transmitter — 1056-based; 2× 4–20 mA; 4 relays; HART option
  • System — Analyzer + sensor(s) + debubbler; single or dual input

Typical applications

  • Filtered drinking-water turbidity.
  • Wastewater discharge monitoring.
  • Clarifier and condensate turbidity.

Selection guide

  • EPA vs ISO sensor
  • Single vs dual input
  • Panel vs back-plate system
  • HART — Digital need

Common mistakes

  • Skipping debubbler on bubbly samples.
  • Infrequent cleaning at higher NTU.
  • Wrong sensor standard for jurisdiction.

When to RFQ / what to tell us

  1. Sensor standard, single/dual, mount.
  2. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU31292
BrandRosemount / Emerson
ModelT1056 Clarity II
Product typeTurbidimeter
TypeClarity II turbidity measurement system (analyzer + sensor + debubbler)
Range0–200 NTU
Resolution0.001 NTU
AccuracyAfter cal at 20 NTU: 0–1 NTU ±2% rdg or ±0.015 NTU; 0–20 NTU ±2% rdg
SensorsUS EPA 180.1 or ISO 7027 compliant options
TransmitterBased on Rosemount 1056; 2× 4–20 mA; 4 alarm relays; HART option
EnclosurePolycarbonate Type 4X / IP65; ½ DIN 155×155×131 mm
InputsSingle or dual turbidity sensor inputs

Documents

FAQ

Q: Range? A: 0–200 NTU with 0.001 NTU resolution.

Q: Sensor standards? A: US EPA 180.1 or ISO 7027 options.

Q: What should I send for a quote? A: Sensor/config, quantity, ship-to.

Links

ParameterValue
AccuracyAfter cal at 20.0 NTU: 0–1 NTU ±2% of reading or ±0.015 NTU (whichever greater); 0–20 NTU ±2% of reading
Wetted partsDelrin, glass, EPDM (sensor/chamber)
Ambient temperature32 to 131 °F (0 to 55 °C); turbidity-only 32 to 122 °F (0 to 50 °C); RH 5–95% non-condensing
Measurement Range0 to 200 NTU class (display resolution 0.001 NTU; accuracy stated after 20.0 NTU calibration for 0–1 and 0–20 NTU bands)
Resolution0.001 NTU (four-digit display; decimal shifts across 0.001–1000 class ranges)
Sensor MethodsUS EPA 180.1 (incandescent) or ISO 7027 (860 nm LED); specified at order
OutputsTwo isolated 0–20/4–20 mA (max load 550 Ω); optional HART on Output 1; four Form-C SPDT alarm relays
EnclosurePolycarbonate Type 4X/CSA 4 (IP65); overall 6.10×6.10×5.5 in (155×155×131 mm); ½ DIN cutout
Power20–30 Vdc (−02) or 85–265 Vac 47.5–65 Hz (−03); 15 W min
Sensor Cable20 ft (6.1 m) or 50 ft (15.2 m) max; IP65 connector when mated
Sample Temperature40 to 95 °F (5 to 35 °C); max pressure 30 psig (308 kPa)
System ContentsSingle/dual-input 1056 analyzer + sensor(s) + debubbler/measuring chamber + cable per sensor
DocumentPDS 00813-0100-3560 Rev AC May 2024