HF Scientific MTOL+ Online Process Turbidimeter
Quote on request
No online payment · add lines to RFQ BOM
MTOL+: online NTU, ultrasonic autoclean, 4–20 mA + Modbus. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
2% of reading or +/-0.02 NTU below 40 NTU (whichever greater); 5% above 40 NTU
Type
HF scientific MTOL+ online process turbidimeter (EPA 180.1 / ISO 7027 models)
Ranges
0-10 NTU pre-calibrated; 0-100 and 0-1000 NTU firmware on USB
Measurement
90 degree nephelometry; resolution 0.001 NTU below 10 NTU
Outputs
Isolated 4-20 mA and RS-485 Modbus simultaneously
Cleaning
Patented ultrasonic autoclean of optical chamber
Continuous nephelometric turbidity monitor for finished or raw water — EPA 180.1 white-light or ISO 7027 infrared models, patented ultrasonic autoclean, and simultaneous isolated 4–20 mA plus RS-485 Modbus.
Key advantages
- Regulatory model choice — White-light cat. 28028 for USEPA Method 180.1; infrared 860 nm LED cat. 28027 for ISO 7027 / DIN 27027.
- Ultrasonic autoclean — Patented optical-chamber cleaning for finished or raw-water service.
- Dual process outputs — Isolated 4–20 mA and RS-485 Modbus at the same time; two programmable Form-C alarms.
- Range flexibility — 0–10 NTU pre-calibrated; 0–100 and 0–1000 NTU firmware on the USB key.
- Field logging / updates — USB for data download and firmware; IP65 sealing; ½ in conduit entry.
Typical applications
- Drinking-water plant effluent turbidity reporting.
- Filter effluent and clarifier monitoring with online NTU trending.
- Raw-water intake turbidity where ultrasonic cleaning reduces optical fouling.
- SCADA integration via 4–20 mA and Modbus RTU.
Selection guide
- Light source — White light (28028) vs infrared (28027) per the method you must meet.
- Range firmware — Keep 0–10 NTU factory config or load 0–100 / 0–1000 from USB.
- Accessories — ProCal kit 39953; ultrasonic cuvette 24166S; mounting plate 28157; optional factory flow alarm.
- Power — 100–240 VAC standard; 24 VDC option per OEM sheet.
Common mistakes
- Ordering infrared when the plant QAPP requires EPA 180.1 white light — or the reverse for ISO 7027 sites.
- Assuming 0–1000 NTU is factory-loaded — higher ranges ship as USB firmware files.
- Skipping ProCal primary standards when verifying low-NTU compliance points.
- Mounting outdoors without weather protection — OEM rates indoor use / IP65 instrument sealing.
When to RFQ / what to tell us
- White light 28028 vs infrared 28027; target NTU range.
- Need for ProCal kit, mounting plate, flow-alarm option, power cord region.
- Quantity and ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 47493 |
| Brand | HF Scientific (Watts) |
| Model | MTOL+ |
| Product type | Online process turbidimeter |
| Measurement | Nephelometry (90° scattered light) |
| Ranges | 0–10 NTU pre-calibrated; 0–100 / 0–1000 NTU via USB firmware |
| Accuracy | 2% of reading or ±0.02 NTU below 40 NTU (greater); 5% above 40 NTU |
| Resolution | 0.001 NTU below 10 NTU (user-selectable) |
| Outputs | Isolated 4–20 mA + RS-485 Modbus simultaneously |
| Alarms | 2 programmable Form-C; optional factory flow alarm |
| Light source | White light tungsten (28028) or IR 860 nm LED (28027) |
| Operating / sample temp | 1–50 °C |
| Inlet pressure | 1–101 psi (7 bar) with regulator set ≈15 psi |
| Power | 100–240 VAC, 47–63 Hz (24 VDC option) |
| Enclosure | IP65; ABS; ½ in conduit |
Documents
FAQ
Q: EPA or ISO — which model? A: White-light 28028 targets USEPA 180.1; infrared 28027 targets ISO 7027 / DIN 27027.
Q: Does ultrasonic cleaning come standard? A: Yes — patented ultrasonic autoclean is standard on MTOL+.
Q: What should I send for a quote? A: Light-source model, NTU range, accessories, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | 2% of reading or +/-0.02 NTU below 40 NTU (whichever greater); 5% above 40 NTU |
| Type | HF scientific MTOL+ online process turbidimeter (EPA 180.1 / ISO 7027 models) |
| Ranges | 0-10 NTU pre-calibrated; 0-100 and 0-1000 NTU firmware on USB |
| Measurement | 90 degree nephelometry; resolution 0.001 NTU below 10 NTU |
| Outputs | Isolated 4-20 mA and RS-485 Modbus simultaneously |
| Cleaning | Patented ultrasonic autoclean of optical chamber |
| Alarms Enclosure | Two programmable C-form alarms; IP65 sealing; 1/2 in conduit |
| Light Source | White light (tungsten) cat 28028 or infrared 860 nm LED cat 28027 |
| Operating | 1 to 50 C; inlet 1-101 psi with regulator set about 15 psi; power 100-240 VAC |
| Document | HF scientific MTOL+ specification sheet S-HF-MTOL_Plus 2510 (watts.com / HFscientific.com) |