HF Scientific M100+ Laboratory Turbidimeter
SKU · 47540 · HF Scientific M100+ Laboratory Turbidimeter
Quote on request
No online payment · add lines to RFQ BOM
M100+: lab NTU 0–4000, touchscreen, USB log. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Range
—
Accuracy
—
Output
—
Benchtop nephelometric turbidimeter for verifying online meters and routine lab NTU work — auto-ranging 0–4000 NTU, color touchscreen, and USB logging, in EPA 180.1 white-light or ISO 7027 infrared versions.
Key advantages
- Auto-range 0–4000 NTU — Nephelometric below 1000 NTU; ratio method above 1000 NTU.
- Method-matched optics — White-light 28060 (USEPA 180.1) or infrared 28061 (ISO 7027).
- Lab-grade resolution — Selectable down to 0.0001 NTU at low readings; response ≤3 s class.
- Touchscreen + USB — Color UI with calibration alert; USB for logged data, cal records, and firmware.
- Ready kit — Ships with ProCal standards set, two cuvettes with light-shield caps, and wall adapter (per OEM ordering notes).
Typical applications
- Grab-sample checks against MTOL+ or other online turbidimeters.
- Plant lab compliance and process troubleshooting NTU work.
- Research / analytical measurements across low to high turbidity.
- Training and method verification with ProCal primary standards.
Selection guide
- Optics — White light 28060 vs infrared 28061 to match the online meter / method.
- Standards — Confirm ProCal kit (39940 white / 39941 IR) or individual standards.
- Cuvettes — Spare 28×70 mm packs 50051 / 50052; lamp assemblies by optics type.
- Environment — Operating 1–40 °C; static (non-flowing) samples for published accuracy.
Common mistakes
- Pairing an infrared lab unit against an EPA 180.1 white-light online meter without method alignment.
- Expecting flowing-sample accuracy — OEM accuracy/repeatability are for static samples.
- Using dirty or scratched cuvettes at sub-0.1 NTU — optical path condition dominates low-end error.
- Skipping the calibration-alert prompt cadence in high-throughput labs.
When to RFQ / what to tell us
- White light 28060 vs infrared 28061.
- Spare ProCal / cuvettes / lamp needs.
- Quantity and ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 47540 |
| Brand | HF Scientific (Watts) |
| Model | M100+ |
| Product type | Laboratory turbidimeter |
| Range | Auto-ranging 0–4000 NTU |
| Measurement | Nephelometric <1000 NTU; ratio >1000 NTU |
| Accuracy | 2% of reading or ±0.02 NTU below 40 NTU (greater); 5% above 40 NTU |
| Repeatability | ≤±1% of reading or ±0.02 NTU (greater); static samples |
| Resolution | Selectable up to 0.0001 NTU |
| Response | ≤3 seconds |
| Sample size | 30 mL (27 mL minimum) |
| Light source | White light tungsten (28060) or IR 860 nm LED (28061) |
| Outputs / data | USB (log download, firmware) |
| Operating temp | 1–40 °C |
| Size / weight | ≈10.75 × 10 × 3.75–4.75 in; about 1.3–2.5 kg class per literature |
Documents
FAQ
Q: How does M100+ relate to MTOL+? A: M100+ is the lab instrument OEM positions for verifying online meters such as MTOL+.
Q: White light or infrared? A: Match the method: 28060 for EPA 180.1; 28061 for ISO 7027.
Q: What should I send for a quote? A: Optics model, spare standards/cuvettes, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Status | Specs pending OEM datasheet merge |