E+H Turbimax CUS51D Turbidity Sensor
E+H Turbimax CUS51D Memosens turbidity/solids sensor: 0–4000 FNU, sludge to ~300 g/L, IP68. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits wastewater and process turbidity/solids loops that need a Memosens digital sensor with formazin turbidity 0–4000 FNU (display to 9999 FNU), sludge solids to ~300 g/L application-dependent, IP68 immersion rating, and Liquiline transmitter pairing.
Key advantages
- 0–4000 FNU formazin — Display to 9999 FNU; sludge solids to ~300 g/L application-dependent.
- Memosens digital — Sensor to Liquiline transmitters; factory formazin calibration path.
- IP68 immersion class — 316L 40 mm sensor body; G1 / NPT ¾ and Flexdip assemblies.
- Process −5…+50 °C — Ambient −20…+60 °C per TI00461C.
Typical applications
- Wastewater turbidity and suspended-solids monitoring.
- Process water loops standardized on Liquiline + Memosens sensors.
- Immersion assemblies (Flexdip CYA112/CYH112) needing digital turbidity.
Selection guide
- Measuring range — Formazin turbidity 0–4000 FNU (display to 9999 FNU); sludge solids to ~300 g/L (application-dependent).
- Accuracy — Factory formazin calibration; application models pre-calibrated; 1–5 point customer calibration.
- Output — Memosens digital to Liquiline transmitters (CUS51D digital sensor).
- Supply — Via Memosens/Liquiline measuring system.
- Process connection — G1 / NPT ¾; Flexdip CYA112/CYH112 immersion assemblies.
- Wetted materials — Stainless steel 316L sensor body.
- Housing — 316L, 40 mm sensor design (~194 mm length).
- IP — IP68 (1 m / 3.3 ft water column with 1N KCl / 60 days per TI).
- Media temperature — Process −5 to +50 °C (23 to 122 °F).
- Ambient — −20 to +60 °C (−4 to +140 °F).
- Communication — Memosens digital protocol.
- Display — Via connected Liquiline transmitter.
- Approvals — CE and regional approvals per TI00461C.
- Notes — Specs from Endress+Hauser TI00461C/07/EN/20.25-00 (2025-10-20) + product page..
Common mistakes
- Ordering without a Liquiline/Memosens transmitter — CUS51D is a digital sensor powered via the measuring system.
- Treating ~300 g/L solids as universal — application-dependent; lock sludge model/calibration on the RFQ.
- Ignoring immersion assembly needs — Flexdip CYA112/CYH112 listed for immersion.
- Exceeding process −5…+50 °C media window.
When to RFQ / what to tell us
- Turbidity vs solids duty, expected FNU/g/L span, and Liquiline transmitter model.
- Process connection (G1 / NPT ¾) vs Flexdip immersion assembly; calibration (factory formazin / 1–5 point).
- Quantity, ship-to, ambient (−20…+60 °C).
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 47605 |
| Brand | Endress+Hauser |
| Model | Turbimax CUS51D |
| Product type | sensor |
| Measuring range | Formazin turbidity 0–4000 FNU (display to 9999 FNU); sludge solids to ~300 g/L (application-dependent) |
| Accuracy | Factory formazin calibration; application models pre-calibrated; 1–5 point customer calibration |
| Output signal | Memosens digital to Liquiline transmitters (CUS51D digital sensor) |
| Supply voltage | Via Memosens/Liquiline measuring system |
| Process connection | G1 / NPT ¾; Flexdip CYA112/CYH112 immersion assemblies |
| Wetted materials | Stainless steel 316L sensor body |
| Housing material | 316L, 40 mm sensor design (~194 mm length) |
| IP rating | IP68 (1 m / 3.3 ft water column with 1N KCl / 60 days per TI) |
| Media temperature | Process −5 to +50 °C (23 to 122 °F) |
| Ambient temperature | −20 to +60 °C (−4 to +140 °F) |
| Communication | Memosens digital protocol |
| Display | Via connected Liquiline transmitter |
| Approvals | CE and regional approvals per TI00461C |
| Notes | Specs from Endress+Hauser TI00461C/07/EN/20.25-00 (2025-10-20) + product page. |
Documents
FAQ
Q: What ranges? A: Formazin turbidity 0–4000 FNU (display to 9999 FNU); sludge solids to ~300 g/L application-dependent.
Q: Which transmitter? A: Memosens digital to Liquiline transmitters — state CM/transmitter family on the RFQ.
Q: What should I send for a quote? A: Duty span, connection/assembly, Liquiline model, quantity. Compatible with systems using E+H Turbimax CUS51D — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Formazin turbidity 0–4000 FNU (display to 9999 FNU); sludge solids to ~300 g/L (application-dependent) |
| Accuracy | Factory formazin calibration; application models pre-calibrated; 1–5 point customer calibration |
| Output | Memosens digital to Liquiline transmitters (CUS51D digital sensor) |
| Supply | Via Memosens/Liquiline measuring system |
| Process connection | G1 / NPT ¾; Flexdip CYA112/CYH112 immersion assemblies |
| Wetted parts | Stainless steel 316L sensor body |
| Housing | 316L, 40 mm sensor design (~194 mm length) |
| Protection | IP68 (1 m / 3.3 ft water column with 1N KCl / 60 days per TI) |
| Media temperature | Process −5 to +50 °C (23 to 122 °F) |
| Ambient temperature | −20 to +60 °C (−4 to +140 °F) |
| Display | Via connected Liquiline transmitter |
| Communication | Memosens digital protocol |
| Approvals | CE and regional approvals per TI00461C |
| Notes | Specs from Endress+Hauser TI00461C/07/EN/20.25-00 (2025-10-20) + product page. |