Image unavailable
Image unavailable
Badger Meter
Badger Meter Industrial Turbo Turbine Flow Meter
Quote on request
No online payment · add lines to RFQ BOM
Industrial Turbo: 2–6 in; ±0.5% prime; ±1.5% extended. RFQ size.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
±0.5% to ±1.5% of indicated flow (range bands per size)
Product Family
Badger Meter Industrial Turbo turbine flow meter (2–4 in. industrial service)
Line Sizes
2 in., 3 in., 4 in.
Repeatability
0.25%
Flow Examples
2 in. ±0.5% band 20–160 gpm / ±1.5% 8–200 gpm; 3 in. 60–350 / 10–450 gpm; 4 in. 100–1000 / 25–1250 gpm
Temperature Range
32–250 °F (0–121 °C)
Fits clean liquid turbine metering in 2–6 in lines where you need a Badger Meter Industrial Turbo—±0.5% accuracy over the prime range (±1.5% extended) with 0.25% repeatability.
Key advantages
- Sizes — 2 / 3 / 4 / 6 in class
- Accuracy — ±0.5% prime; ±1.5% extended
- Repeatability — 0.25%
- Prime examples — 2 in 20–160 gpm; 6 in 250–2,000 gpm class
- Medium — Clean liquids
Typical applications
- Industrial water / process liquids.
- Utility turbine metering.
- Plant transfer lines.
Selection guide
- Size vs flow band
- Register / transmitter options
- Fluid / viscosity limits
Common mistakes
- Sizing on extended range then expecting ±0.5%.
- Dirty / abrasive fluids.
- Insufficient straight run.
When to RFQ / what to tell us
- Size, fluid, flow.
- Register options, quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 35578 |
| Brand | Badger Meter |
| Model | Industrial Turbo |
| Product type | Turbine Flow Meter |
| Type | Industrial turbo turbine flow meter (Badger Meter) |
| Sizes | 2 / 3 / 4 / 6 in class |
| Accuracy | ±0.5% over prime range; ±1.5% extended; repeatability 0.25% |
| Prime ranges | 2 in 20–160 gpm; 3 in 60–350; 4 in 100–1,000; 6 in 250–2,000 gpm class |
| Medium | Clean liquids |
Documents
FAQ
Q: Prime accuracy? A: ±0.5% over the indicated prime range.
Q: Sizes? A: 2, 3, 4, and 6 in class.
Q: What should I send for a quote? A: Size/fluid/flow, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±0.5% to ±1.5% of indicated flow (range bands per size) |
| Product Family | Badger Meter Industrial Turbo turbine flow meter (2–4 in. industrial service) |
| Line Sizes | 2 in., 3 in., 4 in. |
| Repeatability | 0.25% |
| Flow Examples | 2 in. ±0.5% band 20–160 gpm / ±1.5% 8–200 gpm; 3 in. 60–350 / 10–450 gpm; 4 in. 100–1000 / 25–1250 gpm |
| Temperature Range | 32–250 °F (0–121 °C) |
| Min Operating Pressure | 7 psi (0.5 bar) |
| Max Operating Pressure | Standard 125/150 psi (9/10 bar) |
| Bearings | Long-lasting ceramic bearings |
| Outputs | Pickups include open-collector transistor pulse; mechanical/electromechanical options |
| Serviceability | Inline serviceability without removing meter from line |
| Document | TRB-DS-01191-EN (Industrial Turbo Meter PDS) |