Pulsar Measurement

Pulsar Measurement Greyline OCF 6.1 Open Channel Flow Meter

SKU · 47770 · Greyline OCF 6.1 · Brand: Pulsar Measurement
Available
Quote on request
No online payment · add lines to RFQ BOM

Pulsar Greyline OCF 6.1: ultrasonic open-channel; ±0.25% or 2 mm; 4–20 mA; logger. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
±0.25% of range or 2 mm (0.08 in), whichever greater
Approvals
CE, cCSAus; sensor non-incendive Class I Div 2; optional I.S. barriers for Div 1
Type
Non-contacting ultrasonic open-channel flow and tank level meter (Greyline OCF 6.1)
Sensor Range
PZ15: 4.6 m (15 ft); PZ32T: 9.8 m (32 ft)
Deadband
Programmable; minimum 203.2 mm (8 in)
Outputs
Isolated 4–20 mA / 0–5 V; 2× form-C relays 5 A SPDT
Download datasheet PDF

Fits non-contact open-channel flow where you need a Pulsar Measurement Greyline OCF 6.1. Ultrasonic open-channel flow and tank level meter with ±0.25% of range or 2 mm accuracy (whichever greater), PZ15/PZ32T sensors to 4.6/9.8 m, isolated 4–20 mA / 0–5 V, dual 5 A relays and a 26-million-point USB data logger.

Key advantages

  • Accuracy — ±0.25% of range or 2 mm
  • Sensors — PZ15 4.6 m; PZ32T 9.8 m
  • Deadband — Programmable; min 203.2 mm
  • Outputs — 4–20 mA / 0–5 V; 2× Form-C
  • Logging — 26M points; USB

Typical applications

  • Flume / weir flow.
  • Open-channel effluent.
  • Tank non-contact level.

Selection guide

  • Sensor range
  • Primary device
  • Log interval

Common mistakes

  • Deadband too small.
  • Wrong flume equation.
  • Foam / steam interference.

When to RFQ / what to tell us

  1. Sensor/primary device.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47770
BrandPulsar Measurement
ModelGreyline OCF 6.1
Product typeOpen Channel Flow Meter
TypeNon-contacting ultrasonic open-channel flow and tank level meter (Greyline OCF 6.1)
Accuracy±0.25% of range or 2 mm (0.08 in), whichever greater
Sensor rangePZ15: 4.6 m (15 ft); PZ32T: 9.8 m (32 ft)
DeadbandProgrammable; minimum 203.2 mm (8 in)
OutputsIsolated 4–20 mA / 0–5 V; 2× form-C relays 5 A SPDT
LoggingBuilt-in 26-million-point data logger with USB output

Documents

FAQ

Q: Accuracy? A: ±0.25% of range or 2 mm.

Q: Logger? A: 26 million points with USB.

Q: What should I send for a quote? A: Sensor/primary device, quantity, ship-to.

Links

ParameterValue
Accuracy±0.25% of range or 2 mm (0.08 in), whichever greater
ApprovalsCE, cCSAus; sensor non-incendive Class I Div 2; optional I.S. barriers for Div 1
TypeNon-contacting ultrasonic open-channel flow and tank level meter (Greyline OCF 6.1)
Sensor RangePZ15: 4.6 m (15 ft); PZ32T: 9.8 m (32 ft)
DeadbandProgrammable; minimum 203.2 mm (8 in)
OutputsIsolated 4–20 mA / 0–5 V; 2× form-C relays 5 A SPDT
LoggingBuilt-in 26-million-point data logger with USB output
CommunicationsOptional Modbus RTU via RS-485
Electronics Temp−20 °C to 60 °C (−5 °F to 140 °F)
Power100–240 V AC 50/60 Hz; optional 9–32 V DC