UE Ultraprobe 9000 Ultrasonic Inspection
UE Systems Ultraprobe 9000 digital ultrasonic inspection. ~20–100 kHz, DMS logging, IS options. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits plant condition-monitoring rounds that need a handheld digital ultrasonic instrument for bearing checks, compressed-air/gas leak surveys, steam traps, and electrical arcing/corona inspection.
Key advantages
- 20–100 kHz ultrasonic — Adjustable frequency band (ABS PDA rating).
- Multi-duty inspection — Bearings, compressed-air/gas leaks, steam traps/valves, electrical arcing/corona.
- DMS data logging — On-board digital logging with route download/upload and trend charts.
- IS options — FM Class I Div 1 Groups C&D and ATEX Ex ib IIB T3 Gb variants.
Typical applications
- Bearing condition monitoring on plant rounds.
- Compressed-air and gas leak surveys.
- Steam trap / valve inspection and electrical arcing/corona checks.
Selection guide
- Frequency — Adjustable typically 20 kHz to 100 kHz (ABS PDA rating).
- Data logging — On-board digital logging; DMS download/upload of routes and trends.
- Modules — Interchangeable sensing modules for flexible inspection tasks.
- Hazardous area — IS options: FM Class I Div 1 Groups C&D; ATEX Ex ib IIB T3 Gb variants.
- Operating temperature — About 0 to 50 °C (32 to 122 °F) per ABS PDA rating.
- Form — Hand-held pistol-style point-and-listen.
- Software — UE Systems DMS (Excel reporting / trend charts).
Common mistakes
- Ordering a standard kit when the site needs FM Class I Div 1 or ATEX Ex ib IIB T3 Gb — IS is an option variant.
- Skipping sensing-module selection — modules are interchangeable and task-dependent.
- Expecting operation outside ~0…50 °C without checking ABS PDA / OEM limits.
- Assuming DMS licenses/routes are included without stating software needs on the RFQ.
When to RFQ / what to tell us
- Primary duties (bearings / leaks / steam traps / electrical survey) and required sensing modules.
- Intrinsically safe need (FM Class I Div 1 C&D / ATEX Ex ib IIB T3 Gb) yes/no.
- DMS software/route needs, quantity, ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 45909 |
| Brand | UE Systems |
| Model | Ultraprobe 9000 |
| Product type | ultrasonicinspectionsystem |
| Frequency | Adjustable typically 20 kHz to 100 kHz (ABS PDA rating) |
| Applications | Bearings; compressed-air/gas leaks; steam trap/valve; electrical arcing/corona |
| Data logging | On-board digital logging; DMS download/upload of routes and trends |
| Modules | Interchangeable sensing modules |
| Hazardous area | IS options: FM Class I Div 1 Groups C&D; ATEX Ex ib IIB T3 Gb variants |
| Operating temperature | About 0 to 50 °C (32 to 122 °F) per ABS PDA rating |
| Form factor | Hand-held pistol-style point-and-listen |
| Software | UE Systems DMS (Excel reporting / trend charts) |
| Notes | Specs from UE Systems Ultraprobe 9000 brochure EN-UP9000-Website.pdf + ABS/CDA documentation. |
Documents
FAQ
Q: What frequency range does it cover? A: Adjustable ultrasonic frequency typically 20 kHz to 100 kHz per the ABS PDA rating.
Q: Are intrinsically safe versions available? A: Yes — options include FM Class I Div 1 Groups C&D and ATEX Ex ib IIB T3 Gb variants. State the mark required on the RFQ.
Q: What should I send for a quote? A: Duties, modules, IS need, DMS needs, quantity, ship-to. Compatible with systems using UE Ultraprobe 9000 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Hazardous area | Intrinsically safe options including FM Class I Div 1 Groups C&D and ATEX Ex ib IIB T3 Gb variants |
| Type | UE Systems Ultraprobe 9000 digital ultrasonic inspection / condition-monitoring instrument |
| Frequency | Adjustable ultrasonic frequency typically 20 kHz to 100 kHz (ABS PDA rating) |
| Applications | Bearing condition monitoring, compressed-air and gas leak detection, steam trap and valve inspection, electrical arcing/corona survey |
| Data Logging | On-board digital data logging with DMS software download/upload of routes and trend data |
| Modules | Interchangeable sensing modules for flexible inspection tasks |
| Operating Temperature | About 0 to 50 C (32 to 122 F) operating per ABS PDA rating |
| Form Factor | Hand-held pistol-style digital ultrasonic inspection system with point-and-listen operation |
| Software | Compatible with UE Systems DMS for database export, Excel reporting and trend charts |
| Document | UE Systems Ultraprobe 9000 brochure EN-UP9000-Website.pdf + ABS/CDA documentation (uesystems.com) |