UE Systems Ultraprobe 9000 digital ultrasonic inspection. ~20–100 kHz, DMS logging, IS options. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Hazardous area
Intrinsically safe options including FM Class I Div 1 Groups C&D and ATEX Ex ib IIB T3 Gb variants
Type
UE Systems Ultraprobe 9000 digital ultrasonic inspection / condition-monitoring instrument
Frequency
Adjustable ultrasonic frequency typically 20 kHz to 100 kHz (ABS PDA rating)
Applications
Bearing condition monitoring, compressed-air and gas leak detection, steam trap and valve inspection, electrical arcing/corona survey
Data Logging
On-board digital data logging with DMS software download/upload of routes and trend data
Modules
Interchangeable sensing modules for flexible inspection tasks
Download datasheet PDF

Fits plant condition-monitoring rounds that need a handheld digital ultrasonic instrument for bearing checks, compressed-air/gas leak surveys, steam traps, and electrical arcing/corona inspection.

Key advantages

  • 20–100 kHz ultrasonic — Adjustable frequency band (ABS PDA rating).
  • Multi-duty inspection — Bearings, compressed-air/gas leaks, steam traps/valves, electrical arcing/corona.
  • DMS data logging — On-board digital logging with route download/upload and trend charts.
  • IS options — FM Class I Div 1 Groups C&D and ATEX Ex ib IIB T3 Gb variants.

Typical applications

  • Bearing condition monitoring on plant rounds.
  • Compressed-air and gas leak surveys.
  • Steam trap / valve inspection and electrical arcing/corona checks.

Selection guide

  • Frequency — Adjustable typically 20 kHz to 100 kHz (ABS PDA rating).
  • Data logging — On-board digital logging; DMS download/upload of routes and trends.
  • Modules — Interchangeable sensing modules for flexible inspection tasks.
  • Hazardous area — IS options: FM Class I Div 1 Groups C&D; ATEX Ex ib IIB T3 Gb variants.
  • Operating temperature — About 0 to 50 °C (32 to 122 °F) per ABS PDA rating.
  • Form — Hand-held pistol-style point-and-listen.
  • Software — UE Systems DMS (Excel reporting / trend charts).

Common mistakes

  • Ordering a standard kit when the site needs FM Class I Div 1 or ATEX Ex ib IIB T3 Gb — IS is an option variant.
  • Skipping sensing-module selection — modules are interchangeable and task-dependent.
  • Expecting operation outside ~0…50 °C without checking ABS PDA / OEM limits.
  • Assuming DMS licenses/routes are included without stating software needs on the RFQ.

When to RFQ / what to tell us

  1. Primary duties (bearings / leaks / steam traps / electrical survey) and required sensing modules.
  2. Intrinsically safe need (FM Class I Div 1 C&D / ATEX Ex ib IIB T3 Gb) yes/no.
  3. DMS software/route needs, quantity, ship-to country.

Request a Quote · Get selection help

Specs

SpecValue
SKU45909
BrandUE Systems
ModelUltraprobe 9000
Product typeultrasonicinspectionsystem
FrequencyAdjustable typically 20 kHz to 100 kHz (ABS PDA rating)
ApplicationsBearings; compressed-air/gas leaks; steam trap/valve; electrical arcing/corona
Data loggingOn-board digital logging; DMS download/upload of routes and trends
ModulesInterchangeable sensing modules
Hazardous areaIS options: FM Class I Div 1 Groups C&D; ATEX Ex ib IIB T3 Gb variants
Operating temperatureAbout 0 to 50 °C (32 to 122 °F) per ABS PDA rating
Form factorHand-held pistol-style point-and-listen
SoftwareUE Systems DMS (Excel reporting / trend charts)
NotesSpecs from UE Systems Ultraprobe 9000 brochure EN-UP9000-Website.pdf + ABS/CDA documentation.

Documents

FAQ

Q: What frequency range does it cover? A: Adjustable ultrasonic frequency typically 20 kHz to 100 kHz per the ABS PDA rating.

Q: Are intrinsically safe versions available? A: Yes — options include FM Class I Div 1 Groups C&D and ATEX Ex ib IIB T3 Gb variants. State the mark required on the RFQ.

Q: What should I send for a quote? A: Duties, modules, IS need, DMS needs, quantity, ship-to. Compatible with systems using UE Ultraprobe 9000 — we do not claim authorized-dealer status.

Links

ParameterValue
Hazardous areaIntrinsically safe options including FM Class I Div 1 Groups C&D and ATEX Ex ib IIB T3 Gb variants
TypeUE Systems Ultraprobe 9000 digital ultrasonic inspection / condition-monitoring instrument
FrequencyAdjustable ultrasonic frequency typically 20 kHz to 100 kHz (ABS PDA rating)
ApplicationsBearing condition monitoring, compressed-air and gas leak detection, steam trap and valve inspection, electrical arcing/corona survey
Data LoggingOn-board digital data logging with DMS software download/upload of routes and trend data
ModulesInterchangeable sensing modules for flexible inspection tasks
Operating TemperatureAbout 0 to 50 C (32 to 122 F) operating per ABS PDA rating
Form FactorHand-held pistol-style digital ultrasonic inspection system with point-and-listen operation
SoftwareCompatible with UE Systems DMS for database export, Excel reporting and trend charts
DocumentUE Systems Ultraprobe 9000 brochure EN-UP9000-Website.pdf + ABS/CDA documentation (uesystems.com)