Key parameters

Ac Voltage
0 to 480 V AC; LCD indication steps 6/12/24/50/230/400/690 V (family scale)
Ac Accuracy
±(1.5% of reading + 5 digits); resolution 1 V
Dc Voltage
0 to 690 V DC
Dc Accuracy
±(1.0% of reading + 3 digits); resolution 1 V
Continuity
0 to 200 kΩ, guaranteed on <50 kΩ; audible tone
Low Impedance
12–250 V AC/DC; impedance <6 kΩ; two-handed low-Z testing
Download datasheet PDF

Fits two-pole voltage and continuity checks where you need an Extech VT30 covering AC to 480 V and DC to 690 V with low-impedance testing, polarity LEDs, and CAT III/IV 600 V safety.

Key advantages

  • AC — 0 to 480 V AC; ±(1.5% + 5 digits); LCD step scale family
  • DC — 0 to 690 V DC; ±(1.0% + 3 digits)
  • Continuity — 0 to 200 kΩ; guaranteed on <50 kΩ; audible
  • Low-Z — 12–250 V AC/DC; impedance <6 kΩ; two-handed low-Z
  • Safety / build — CAT III 600 V / CAT IV 600 V; IP64 rubberized; flashlight; 2× AAA

Typical applications

  • Electrician voltage presence checks.
  • Continuity and polarity verification.
  • Low-Z tests to reduce ghost voltage.

Selection guide

  • Low-Z use — Ghost voltage situations
  • CAT rating — Match installation category
  • Flashlight — Dark panels
  • Power — AAA batteries

Common mistakes

  • Relying on low-Z on circuits that cannot tolerate load.
  • Exceeding CAT III/IV 600 V limits.
  • Single-handed misuse of two-pole tester.

When to RFQ / what to tell us

  1. Accessories; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU24446
BrandExtech
ModelVT30
Product typeVoltage Tester
AC voltage0 to 480 V AC; LCD indication steps 6/12/24/50/230/400/690 V (family scale)
AC accuracy±(1.5% of reading + 5 digits); resolution 1 V
DC voltage0 to 690 V DC
DC accuracy±(1.0% of reading + 3 digits); resolution 1 V
Continuity0 to 200 kΩ, guaranteed on <50 kΩ; audible tone
Low impedance12–250 V AC/DC; impedance <6 kΩ; two-handed low-Z testing
Input impedanceapprox. 1 MΩ
Frequency50/60 Hz
SafetyCAT III 600 V / CAT IV 600 V; EN61010-1; CE
HousingRubberized double-molded IP64 with built-in flashlight; polarity LEDs
Power2× AAA (1.5 V)
Dimensions/weight240 × 78 × 40 mm; approx. 237–260 g

Documents

FAQ

Q: AC/DC ranges? A: AC to 480 V; DC to 690 V.

Q: Safety? A: CAT III 600 V / CAT IV 600 V; EN61010-1; CE.

Q: What should I send for a quote? A: Quantity and ship-to.

Links

ParameterValue
Ac Voltage0 to 480 V AC; LCD indication steps 6/12/24/50/230/400/690 V (family scale)
Ac Accuracy±(1.5% of reading + 5 digits); resolution 1 V
Dc Voltage0 to 690 V DC
Dc Accuracy±(1.0% of reading + 3 digits); resolution 1 V
Continuity0 to 200 kΩ, guaranteed on <50 kΩ; audible tone
Low Impedance12–250 V AC/DC; impedance <6 kΩ; two-handed low-Z testing
Input Impedanceapprox. 1 MΩ
Frequency Bandwidth50/60 Hz
Safety CategoryCAT III 600 V / CAT IV 600 V; EN61010-1; CE
HousingRubberized double-molded IP64 with built-in flashlight; polarity LEDs
Power2× AAA (1.5 V)
Dimensions Weight240 × 78 × 40 mm; approx. 237–260 g