Image unavailable
Image unavailable
Endress+Hauser
Endress+Hauser Proline Prowirl F 200 Vortex Flow Meter
Quote on request
No online payment · add lines to RFQ BOM
E+H Prowirl F 200: vortex; DN 15–300; ±0.75% liquid; ±1.0% gas/steam; to +400 °C. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Wetted parts
CF3M/1.4408 measuring tube; 1.4404/F316/F316L flanges; Alloy C22 options
Protection
IP66/67, Type 4X enclosure
Approvals
SIL, ATEX/IECEx/cCSAus and other Haz.area options
Measuring Principle
Karman vortex street (ISO 12764)
Nominal Diameter
DN 15 to 300 (½ to 12") flanged
Volume Flow Accuracy Liquid
±0.75 % of reading (Re ≥ 10 000, standard)
Fits steam, gas and liquid vortex metering where you need an Endress+Hauser Proline Prowirl F 200. Karman vortex meter for DN 15–300 with liquid volume accuracy ±0.75% of reading (Re ≥ 10,000), gas/steam ±1.0%, medium temperature −40 to +260 °C standard (−200 to +400 °C options) and PN/Class pressure ratings by order code.
Key advantages
- Principle — Karman vortex (ISO 12764)
- DN — 15 to 300 (½ to 12")
- Liquid accuracy — ±0.75% o.r. (Re ≥ 10,000)
- Gas/steam — ±1.0% o.r.
- Temperature — −40…+260 °C std; to +400 °C options
Typical applications
- Steam energy metering.
- Gas utility vortex.
- Liquid volumetric vortex.
Selection guide
- DN / pressure class
- Temp option
- I/O / HART
Common mistakes
- Re too low.
- Wrong temp option.
- Two-phase without care.
When to RFQ / what to tell us
- DN/pressure/temp/I/O.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 47037 |
| Brand | Endress+Hauser |
| Model | Proline Prowirl F 200 |
| Product type | Vortex Flow Meter |
| Measuring principle | Karman vortex street (ISO 12764) |
| Nominal diameter | DN 15 to 300 (½ to 12") flanged |
| Volume flow accuracy liquid | ±0.75 % of reading (Re ≥ 10 000, standard) |
| Volume flow accuracy gas/steam | ±1.0 % of reading (Re ≥ 10 000, standard) |
| Medium temperature range | Standard –40 to +260 °C; high/low-temp options –200 to +400 °C |
| Max process pressure | PN 10 to 100 / Class 150 to 600 (order-code dependent) |
Documents
FAQ
Q: Liquid accuracy? A: ±0.75% o.r. (Re ≥ 10,000).
Q: DN? A: 15 to 300.
Q: What should I send for a quote? A: DN/pressure/temp/I/O, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Wetted parts | CF3M/1.4408 measuring tube; 1.4404/F316/F316L flanges; Alloy C22 options |
| Protection | IP66/67, Type 4X enclosure |
| Approvals | SIL, ATEX/IECEx/cCSAus and other Haz.area options |
| Measuring Principle | Karman vortex street (ISO 12764) |
| Nominal Diameter | DN 15 to 300 (½ to 12") flanged |
| Volume Flow Accuracy Liquid | ±0.75 % of reading (Re ≥ 10 000, standard) |
| Volume Flow Accuracy Gas Steam | ±1.0 % of reading (Re ≥ 10 000, standard) |
| Medium Temperature Range | Standard –40 to +260 °C; high/low-temp options –200 to +400 °C |
| Max Process Pressure | PN 10 to 100 / Class 150 to 600 (order-code dependent) |
| Outputs | 4–20 mA HART; pulse/frequency/switch; Ethernet options; PROFINET over Ethernet-APL |
| Power Supply | Loop-powered DC 12 to 35 V (Proline 200) |
| Special Features | Wet steam detection/measurement packages; Heartbeat Technology; dual-compartment housing |
| Versions | Compact or remote transmitter |