Endress+Hauser

Endress+Hauser Proline Prowirl F 200 Vortex Flow Meter

SKU · 47037 · Proline Prowirl F 200 · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Prowirl F 200: vortex; DN 15–300; ±0.75% liquid; ±1.0% gas/steam; to +400 °C. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Wetted parts
CF3M/1.4408 measuring tube; 1.4404/F316/F316L flanges; Alloy C22 options
Protection
IP66/67, Type 4X enclosure
Approvals
SIL, ATEX/IECEx/cCSAus and other Haz.area options
Measuring Principle
Karman vortex street (ISO 12764)
Nominal Diameter
DN 15 to 300 (½ to 12") flanged
Volume Flow Accuracy Liquid
±0.75 % of reading (Re ≥ 10 000, standard)
Download datasheet PDF

Fits steam, gas and liquid vortex metering where you need an Endress+Hauser Proline Prowirl F 200. Karman vortex meter for DN 15–300 with liquid volume accuracy ±0.75% of reading (Re ≥ 10,000), gas/steam ±1.0%, medium temperature −40 to +260 °C standard (−200 to +400 °C options) and PN/Class pressure ratings by order code.

Key advantages

  • Principle — Karman vortex (ISO 12764)
  • DN — 15 to 300 (½ to 12")
  • Liquid accuracy — ±0.75% o.r. (Re ≥ 10,000)
  • Gas/steam — ±1.0% o.r.
  • Temperature — −40…+260 °C std; to +400 °C options

Typical applications

  • Steam energy metering.
  • Gas utility vortex.
  • Liquid volumetric vortex.

Selection guide

  • DN / pressure class
  • Temp option
  • I/O / HART

Common mistakes

  • Re too low.
  • Wrong temp option.
  • Two-phase without care.

When to RFQ / what to tell us

  1. DN/pressure/temp/I/O.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47037
BrandEndress+Hauser
ModelProline Prowirl F 200
Product typeVortex Flow Meter
Measuring principleKarman vortex street (ISO 12764)
Nominal diameterDN 15 to 300 (½ to 12") flanged
Volume flow accuracy liquid±0.75 % of reading (Re ≥ 10 000, standard)
Volume flow accuracy gas/steam±1.0 % of reading (Re ≥ 10 000, standard)
Medium temperature rangeStandard –40 to +260 °C; high/low-temp options –200 to +400 °C
Max process pressurePN 10 to 100 / Class 150 to 600 (order-code dependent)

Documents

FAQ

Q: Liquid accuracy? A: ±0.75% o.r. (Re ≥ 10,000).

Q: DN? A: 15 to 300.

Q: What should I send for a quote? A: DN/pressure/temp/I/O, quantity, ship-to.

Links

ParameterValue
Wetted partsCF3M/1.4408 measuring tube; 1.4404/F316/F316L flanges; Alloy C22 options
ProtectionIP66/67, Type 4X enclosure
ApprovalsSIL, ATEX/IECEx/cCSAus and other Haz.area options
Measuring PrincipleKarman vortex street (ISO 12764)
Nominal DiameterDN 15 to 300 (½ to 12") flanged
Volume Flow Accuracy Liquid±0.75 % of reading (Re ≥ 10 000, standard)
Volume Flow Accuracy Gas Steam±1.0 % of reading (Re ≥ 10 000, standard)
Medium Temperature RangeStandard –40 to +260 °C; high/low-temp options –200 to +400 °C
Max Process PressurePN 10 to 100 / Class 150 to 600 (order-code dependent)
Outputs4–20 mA HART; pulse/frequency/switch; Ethernet options; PROFINET over Ethernet-APL
Power SupplyLoop-powered DC 12 to 35 V (Proline 200)
Special FeaturesWet steam detection/measurement packages; Heartbeat Technology; dual-compartment housing
VersionsCompact or remote transmitter