Endress+Hauser

Endress+Hauser Proline Prowirl D 200 Vortex Flow Meter

SKU · 47331 · Proline Prowirl D 200 · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Prowirl D 200: wafer vortex; DN 15–150; 65 mm FTF; ±0.75% liquid; ±1% gas. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Wetted parts
Stainless steel CF3M/1.4408 measuring tube
Protection
IP66/67, Type 4X enclosure
Approvals
SIL and worldwide Haz.area options
Measuring Principle
Karman vortex street
Nominal Diameter
DN 15 to 150 (½ to 6") wafer (disc)
Face To Face
65 mm (2.56 in)
Download datasheet PDF

Fits short-face-to-face vortex metering where you need an Endress+Hauser Proline Prowirl D 200. Wafer (disc) Karman vortex meter for DN 15–150 with 65 mm face-to-face, liquid volume accuracy under 0.75%, gas/steam under 1.0%, and temperature options −40/+260 °C standard with HT to +400 °C.

Key advantages

  • Form — Wafer / disc; 65 mm FTF
  • DN — 15 to 150 (½ to 6")
  • Liquid accuracy — <0.75%
  • Gas/steam — <1.0%
  • Temperature — −40/+260 °C; HT to +400 °C

Typical applications

  • Compact steam vortex.
  • Wafer gas/liquid vortex.
  • Short-lay-length installs.

Selection guide

  • DN / gasket
  • Temp option
  • I/O / HART

Common mistakes

  • Wrong wafer alignment.
  • Re too low.
  • Missing centering rings.

When to RFQ / what to tell us

  1. DN/temp/I/O.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47331
BrandEndress+Hauser
ModelProline Prowirl D 200
Product typeVortex Flow Meter
Measuring principleKarman vortex street
Nominal diameterDN 15 to 150 (½ to 6") wafer (disc)
Face to face65 mm (2.56 in)
Volume flow accuracy liquid< 0.75 % (Re2 to Remax, incompressible, standard)
Volume flow accuracy gas/steam< 1.0 % (Re2 to Remax, compressible, standard)
Medium temperature rangeStandard and high-temperature DSC sensor options −40/+260 °C; HT to +400 °C

Documents

FAQ

Q: FTF? A: 65 mm.

Q: DN? A: 15 to 150.

Q: What should I send for a quote? A: DN/temp/I/O, quantity, ship-to.

Links

ParameterValue
Wetted partsStainless steel CF3M/1.4408 measuring tube
ProtectionIP66/67, Type 4X enclosure
ApprovalsSIL and worldwide Haz.area options
Measuring PrincipleKarman vortex street
Nominal DiameterDN 15 to 150 (½ to 6") wafer (disc)
Face To Face65 mm (2.56 in)
Volume Flow Accuracy Liquid< 0.75 % (Re2 to Remax, incompressible, standard)
Volume Flow Accuracy Gas Steam< 1.0 % (Re2 to Remax, compressible, standard)
Medium Temperature RangeStandard and high-temperature DSC sensor options per TI (typ. –40/+260 °C; HT to +400 °C)
Process ConnectionsWafer between EN 1092-1 PN 10/16/25/40 or ASME B16.5 Class 150/300 flanges
Outputs4–20 mA HART; pulse/frequency/switch; Ethernet options
Power SupplyLoop-powered Proline 200
Special FeaturesLow weight wafer body; centering rings; Heartbeat Technology