Image unavailable
Image unavailable
Waltron
Waltron 3141 Silica Analyzer
Quote on request
No online payment · add lines to RFQ BOM
Waltron 3141: online colorimetric silica; 0–1000 ppb / 0–5 / 0–150 ppm; ±1 ppb/±2%. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
+/-1 ppb or +/-2% of reading (whichever is greater)
Type
Online colorimetric dissolved silica analyzer (Waltron 3141)
Parameter
Silica
Technology
Colorimetric
Ranges
0-1000 ppb; 0-5 ppm; 0-150 ppm
Sample Streams
1 to 2
Fits online dissolved silica monitoring where you need a Waltron 3141. Colorimetric silica analyzer with ranges 0–1000 ppb, 0–5 ppm and 0–150 ppm, accuracy ±1 ppb or ±2% of reading whichever greater, for continuous water-chemistry silica measurement.
Key advantages
- Parameter — Dissolved silica
- Technology — Colorimetric
- Ranges — 0–1000 ppb; 0–5 ppm; 0–150 ppm
- Accuracy — ±1 ppb or ±2% rdg
- Form — Online analyzer
Typical applications
- Boiler / condensate silica.
- Demin plant monitoring.
- Ultrapure water silica.
Selection guide
- Range code
- Sample conditioning
- Reagent kit
Common mistakes
- Wrong range for expected ppb.
- Dirty sample lines.
- Reagent expiry.
When to RFQ / what to tell us
- Range/options.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 49532 |
| Brand | Waltron |
| Model | 3141 Silica Analyzer |
| Product type | Silica Analyzer |
| Type | Online colorimetric dissolved silica analyzer (Waltron 3141) |
| Parameter | Silica |
| Technology | Colorimetric |
| Ranges | 0-1000 ppb; 0-5 ppm; 0-150 ppm |
| Accuracy | +/-1 ppb or +/-2% of reading (whichever is greater) |
Documents
FAQ
Q: Ranges? A: 0–1000 ppb; 0–5 ppm; 0–150 ppm.
Q: Accuracy? A: ±1 ppb or ±2% of reading.
Q: What should I send for a quote? A: Range/options, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | +/-1 ppb or +/-2% of reading (whichever is greater) |
| Type | Online colorimetric dissolved silica analyzer (Waltron 3141) |
| Parameter | Silica |
| Technology | Colorimetric |
| Ranges | 0-1000 ppb; 0-5 ppm; 0-150 ppm |
| Sample Streams | 1 to 2 |
| Response Cycle | About 12 min batch response; 20 min cycle adjustable |
| Outputs | 4-20 mA (galvanic isolator option) or 0-5 V; 2 or 4 configurable alarms |
| Calibration | Automatic calibration and validation (QA/QC); grab sample capability |
| Enclosure Power | IP65/NEMA4X; 110-220 VAC; panel/wall mount |
| Dimensions Weight | 24 x 15 x 8.5 in (60 x 38 x 21 cm); 17 kg (38 lb) |
| Document | Waltron 3141 Silica Analyzer Product Sheet (20250709) |