E+E EE260 Meteorological Humidity & Temperature Probe

SKU · 47852 · E+E EE260 Meteorological Humidity and Temperature Probe
Available
Quote on request
No online payment · add lines to RFQ BOM

EE260: heated RH/T meteo probe, IP67, Modbus + voltage outs. RFQ + selection help.

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Range
—
Accuracy
—
Output
—

Outdoor meteorological RH/T probe with dual heating (sensing element + probe head) for reliable readings in permanent high humidity — IP67 elastomer body, PTFE filter, dual voltage outputs, and RS-485 Modbus RTU.

Key advantages

  • Dual heating — Heated RH element and heated sensing head resist condensation/icing and recover quickly after wet events.
  • Meteo ranges — RH 0–100%; temperature −60 to +60 °C with integrated Pt100 1/3 DIN B.
  • Analog + digital together — Two freely scalable voltage outputs (0–1 / 2.5 / 5 / 10 V) plus RS-485 Modbus RTU.
  • Calculated humidity quantities — Td, Tf, Tw, e, mixing ratio, absolute humidity, enthalpy on the digital interface.
  • Outdoor-ready build — IP67 UV/heat-stable elastomer, encapsulated electronics, E+E coating, M12×1 8-pole stainless connector.

Typical applications

  • Meteorological weather stations in radiation shields.
  • Road / airport weather warning and icing-hazard detection.
  • High-humidity outdoor monitoring where unheated probes fog or ice.
  • SCADA / logger integration via Modbus or voltage outputs.

Selection guide

  • Outputs — Map which quantities go to the two voltage channels vs Modbus registers.
  • Shield compatibility — Compact design fits commercially available rotationally symmetric radiation shields.
  • Configuration — Optional adapter + free PCS10 software for setup and adjustment.
  • Supply — 7–30 V DC; typical ≈300 mW including heating.

Common mistakes

  • Mounting without a radiation shield in direct sun — temperature and RH errors climb.
  • Expecting storage in condensing humidity — OEM storage RH is 0–95% non-condensing.
  • Wiring only one interface when the job needs both analog and Modbus simultaneously — both are available at once.
  • Skipping the PTFE filter / coating discussion for dusty or corrosive sites.

When to RFQ / what to tell us

  1. Voltage-output scaling and Modbus address/baud needs.
  2. Cable / configuration-adapter / radiation-shield requirements.
  3. Quantity and ship-to country.

Request a Quote · Get selection help

Specs

SpecValue
SKU47852
BrandE+E Elektronik
ModelEE260
Product typeHeated meteorological humidity and temperature probe
RH range / accuracy0–100% RH; ±1.3% RH class (−15…40 °C, ≤90% RH) per OEM page
Temperature range−60…+60 °C (−76…140 °F)
Temperature accuracyAnalogue ≈0.15 °C; digital ≈0.1 °C (OEM page)
RH sensorE+E HMC01 heated; t90 <15 s at 20 °C
Outputs2× voltage 0–1/2.5/5/10 V; RS-485 Modbus RTU
Supply7–30 V DC; typ. 300 mW incl. heating
Connector / filterM12×1 8-pole stainless; PTFE membrane on SS body
EnclosureIP67 thermoplastic elastomer, UV resistant
Operating conditions−60…60 °C; 0…100% RH (operation)

Documents

FAQ

Q: Why is the probe heated? A: Dual heating keeps the RH element and head free of condensation/icing so readings stay usable in permanent high humidity.

Q: Can I use voltage outputs and Modbus together? A: Yes — OEM states measured data are available on analog and digital interfaces simultaneously.

Q: What should I send for a quote? A: Output mapping, cable/adapter/shield needs, quantity, ship-to.

Links

ParameterValue
StatusSpecs pending OEM datasheet merge