Rosemount 3300HT / 3300HTVP pH Sensor
Rosemount 3300HT/3300HTVP PERpH-X pH/ORP sensor to 155 °C / 400 psig class. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits high-temperature and harsh liquid-analysis loops that need a PERpH-X pH/ORP sensor (3300HT integral or 3300HTVP Variopol) with media temperature up to 155 °C class and process pressure up to 400 psig class, option-dependent.
Key advantages
- High-temp PERpH-X — Media temperature up to 155 °C (311 °F) class, option-dependent.
- 400 psig class — Process pressure up to 400 psig class, model/option dependent.
- Integral or Variopol — 3300HT integral cable or 3300HTVP VP8 quick-disconnect.
- Selectable electrolytes — Reference options for HT / biofilm / poison / oil / scale duty.
Typical applications
- High-temperature pH/ORP loops in chemical and process liquids.
- Harsh media where PERpH-X reference electrolytes are specified.
- Installs that need Variopol VP8 quick-disconnect sensor changeout.
Selection guide
- Family — High-performance PERpH-X pH/ORP (3300HT integral; 3300HTVP Variopol).
- Accuracy — Transmitter-dependent; selectable reference electrolytes for HT/biofilm/poison/oil/scale duty.
- Output — Sensor mV to Rosemount liquid analysis transmitters; VP8 option on 3300HTVP.
- Process connection — Insertion/submersion styles per 00813-0100-3300 ordering information.
- Wetted materials — Ryton® / titanium options; glass pH/ORP electrodes; PERpH-X reference system.
- Media temperature — Up to 155 °C (311 °F) class (model/option dependent).
- Process pressure — Up to 400 psig class (model/option dependent).
- Communication — VP8 interconnect (3300HTVP); SMART options per PDS.
- Approvals — Calibration/conformance certificate options per PDS.
Common mistakes
- Ordering 3300HT integral when the install needs Variopol VP8 quick-disconnect — choose 3300HTVP.
- Assuming transmitter accuracy equals the sensor — accuracy is transmitter-dependent; lock transmitter model on the RFQ.
- Ignoring that 155 °C / 400 psig class are model/option dependent — confirm on the chosen order code.
- Leaving electrolyte / media chemistry blank when biofilm, poison, oil, or scale duty drives the reference choice.
When to RFQ / what to tell us
- 3300HT vs 3300HTVP, media chemistry, and required temperature/pressure class.
- Insertion/submersion style, wetted materials, and matching Rosemount transmitter model.
- Certificate options, quantity, ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 36545 |
| Brand | Rosemount |
| Model | 3300HT / 3300HTVP |
| Product type | sensor |
| Measuring range | High-performance PERpH-X pH/ORP (3300HT integral; 3300HTVP Variopol) |
| Accuracy | Transmitter-dependent; selectable reference electrolytes for HT/biofilm/poison/oil/scale duty |
| Output signal | Sensor mV to Rosemount liquid analysis transmitters; VP8 option on 3300HTVP |
| Supply voltage | Via compatible Rosemount transmitter |
| Process connection | Insertion/submersion styles per 00813-0100-3300 ordering information |
| Wetted materials | Ryton® / titanium options; glass pH/ORP electrodes; PERpH-X reference system |
| Housing material | Per sensor body codes in PDS |
| IP rating | Process sensor rating per PDS installation section |
| Media temperature | Up to 155 °C (311 °F) class (model/option dependent) |
| Ambient temperature | Per PDS tables |
| Process pressure | Up to 400 psig class (model/option dependent) |
| Communication | VP8 interconnect (3300HTVP); SMART options per PDS |
| Display | N/A (sensor) |
| Approvals | Calibration/conformance certificate options per PDS |
| Notes | Specs from Emerson PDS 00813-0100-3300 Rev AD (Oct 2022) covering 3300HT/3300HTVP family. |
Documents
FAQ
Q: 3300HT vs 3300HTVP? A: 3300HT is integral cable; 3300HTVP adds Variopol VP8 quick-disconnect. Both are PERpH-X high-performance pH/ORP sensors.
Q: What T/P class? A: Media temperature up to 155 °C (311 °F) class and process pressure up to 400 psig class — model/option dependent; confirm on PDS charts.
Q: What should I send for a quote? A: HT vs HTVP, connection, materials, transmitter, T/P, duty, quantity. Compatible with systems using Rosemount 3300HT — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | High-performance PERpH-X pH/ORP (3300HT integral; 3300HTVP Variopol) |
| Accuracy | Transmitter-dependent; selectable reference electrolytes for HT/biofilm/poison/oil/scale duty |
| Output | Sensor mV to Rosemount liquid analysis transmitters; VP8 option on 3300HTVP |
| Supply | Via compatible Rosemount transmitter |
| Process connection | Insertion/submersion styles per 00813-0100-3300 ordering information |
| Wetted parts | Ryton® / titanium options; glass pH/ORP electrodes; PERpH-X reference system |
| Housing | Per sensor body codes in PDS |
| Protection | Process sensor rating per PDS installation section |
| Media temperature | Up to 155 °C (311 °F) class (model/option dependent) |
| Ambient temperature | Per PDS tables |
| Display | N/A (sensor) |
| Communication | VP8 interconnect (3300HTVP); SMART options per PDS |
| Approvals | Calibration/conformance certificate options per PDS |
| Notes | Specs from Emerson PDS 00813-0100-3300 Rev AD (Oct 2022) covering 3300HT/3300HTVP family. |
| Process Pressure | Up to 400 psig class (model/option dependent) |