Parámetros clave

Type
High-power cast-aluminum circulation heater (CAST-X 4000)
Power
12.5 kW to 60 kW total; 208–480 V; max 50 A per circuit
Tubing
1.0 in OD × 0.083 in wall; 212 in process tube length each; 316L SS standard (Inconel optional)
Max Pressure
3100 psi (213 bar)
Enclosures
NEMA 4 (moisture-resistant) or NEMA 7 / ATEX (explosion-proof)
Max Working Temperature
NEMA 4: 572 °F (300 °C); NEMA 7/ATEX: 662 °F (350 °C)
Descargar datasheet PDF
ParámetroValor
TypeHigh-power cast-aluminum circulation heater (CAST-X 4000)
Power12.5 kW to 60 kW total; 208–480 V; max 50 A per circuit
Tubing1.0 in OD × 0.083 in wall; 212 in process tube length each; 316L SS standard (Inconel optional)
Max Pressure3100 psi (213 bar)
EnclosuresNEMA 4 (moisture-resistant) or NEMA 7 / ATEX (explosion-proof)
Max Working TemperatureNEMA 4: 572 °F (300 °C); NEMA 7/ATEX: 662 °F (350 °C)
SensorsK or J thermocouples standard; RTD available
Media PathMedia isolated in seamless SS flow tubes — no contact with heating elements
ModesSingle-tube or dual-tube (series or parallel)