KROHNE

KROHNE OPTIMASS 6000 Coriolis Mass Flow Meter

SKU · 42316 · OPTIMASS 6000 · Marca: KROHNE
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Measuring Principle
Coriolis mass flow (twin V-shaped measuring tube)
Family
OPTIMASS 6000 sensor + MFC 400 → OPTIMASS 6400C/F meter
Connection Sizes
DN10…300 / ½…12 in (sensor family; DN08…250 by tube material)
Tube Material
Stainless steel 316L, Hastelloy, or Duplex stainless steel
Process Temperature
−200…+400 °C by version (cryogenic / high-temperature options)
Process Pressure
Up to ~100 barg (SS) / ~200 barg (Hastelloy/Duplex) @ 20 °C typical
Descargar datasheet PDF
ParámetroValor
Measuring PrincipleCoriolis mass flow (twin V-shaped measuring tube)
FamilyOPTIMASS 6000 sensor + MFC 400 → OPTIMASS 6400C/F meter
Connection SizesDN10…300 / ½…12 in (sensor family; DN08…250 by tube material)
Tube MaterialStainless steel 316L, Hastelloy, or Duplex stainless steel
Process Temperature−200…+400 °C by version (cryogenic / high-temperature options)
Process PressureUp to ~100 barg (SS) / ~200 barg (Hastelloy/Duplex) @ 20 °C typical
Accuracy LiquidLiquid ±0.1% of rate (optional ±0.05%); gas ±0.35% of rate ± zero stability
Measured ValuesMass, density, temperature; calculated volume / concentration / velocity
DesignFully welded maintenance-free sensor; compact or remote converter
ApplicationCryogenic / LNG, high-temp process, tanker loading, CIP/SIP >130 °C
DocumentTD OPTIMASS 6000 R06 (4001894106) + MA OPTIMASS 6000 R08