Micro Motion

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

SKU · 42317 · H-Series Hygienic Coriolis Flow Meters · Marca: Micro Motion
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Type
Hygienic Coriolis flow and density meters (Micro Motion H-Series)
Mass Accuracy
Liquid mass accuracy up to ±0.05%
Density Accuracy
Liquid density accuracy up to ±0.5 kg/m³
Design
Cleanable self-draining compact hygienic sensor
Wetted
316L stainless; surface finish up to 15 Ra (0.38 μm)
Io
HART, Profibus-DP, FOUNDATION fieldbus, 4–20 mA, wireless options
Descargar datasheet PDF
ParámetroValor
TypeHygienic Coriolis flow and density meters (Micro Motion H-Series)
Mass AccuracyLiquid mass accuracy up to ±0.05%
Density AccuracyLiquid density accuracy up to ±0.5 kg/m³
DesignCleanable self-draining compact hygienic sensor
Wetted316L stainless; surface finish up to 15 Ra (0.38 μm)
IoHART, Profibus-DP, FOUNDATION fieldbus, 4–20 mA, wireless options
HygienicASME BPE / 3-A / EHEDG class service; SIP/CIP capable
DiagnosticsSmart Meter Verification standard
CalibrationISO/IEC 17025 calibration stands ±0.014% uncertainty class
DocumentPS-00599 Micro Motion H-Series product data sheet