Parámetros clave
Type
Hygienic Coriolis flow and density meters (Micro Motion H-Series)
Mass Accuracy
Liquid mass accuracy up to ±0.05%
Density Accuracy
Liquid density accuracy up to ±0.5 kg/m³
Design
Cleanable self-draining compact hygienic sensor
Wetted
316L stainless; surface finish up to 15 Ra (0.38 μm)
Io
HART, Profibus-DP, FOUNDATION fieldbus, 4–20 mA, wireless options
| Parámetro | Valor |
|---|---|
| Type | Hygienic Coriolis flow and density meters (Micro Motion H-Series) |
| Mass Accuracy | Liquid mass accuracy up to ±0.05% |
| Density Accuracy | Liquid density accuracy up to ±0.5 kg/m³ |
| Design | Cleanable self-draining compact hygienic sensor |
| Wetted | 316L stainless; surface finish up to 15 Ra (0.38 μm) |
| Io | HART, Profibus-DP, FOUNDATION fieldbus, 4–20 mA, wireless options |
| Hygienic | ASME BPE / 3-A / EHEDG class service; SIP/CIP capable |
| Diagnostics | Smart Meter Verification standard |
| Calibration | ISO/IEC 17025 calibration stands ±0.014% uncertainty class |
| Document | PS-00599 Micro Motion H-Series product data sheet |