Endress+Hauser

Endress+Hauser Proline Promass E 300 Coriolis Flow Meter

SKU · 45666 · Proline Promass E 300 · Marca: Endress+Hauser
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Measuring range
0 to 180 000 kg/h (0 to 6615 lb/min); DN 8 to 80 (⅜ to 3")
Accuracy
Mass flow liquid ±0.15% standard / ±0.10% option; volume liquid ±0.15%; gas mass ±0.50%; density liquid ±0.0005 g/cm³
Output
Up to 3 freely combinable I/Os; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP; WLAN/web server
Supply
Per Proline 300 transmitter power supply order code
Process connection
Flanges and process connections per TI (SST 1.4404 typical)
Wetted parts
Measuring tubes 1.4539 (904L); connections 1.4404 (316/316L); sensor housing 1.4301 (304)
Descargar datasheet PDF
ParámetroValor
Measuring range0 to 180 000 kg/h (0 to 6615 lb/min); DN 8 to 80 (⅜ to 3")
AccuracyMass flow liquid ±0.15% standard / ±0.10% option; volume liquid ±0.15%; gas mass ±0.50%; density liquid ±0.0005 g/cm³
OutputUp to 3 freely combinable I/Os; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP; WLAN/web server
SupplyPer Proline 300 transmitter power supply order code
Process connectionFlanges and process connections per TI (SST 1.4404 typical)
Wetted partsMeasuring tubes 1.4539 (904L); connections 1.4404 (316/316L); sensor housing 1.4301 (304)
HousingProline 300 dual-compartment aluminum coated or stainless hygienic
ProtectionPer TI Degree of protection
Media temperature−40 to +150 °C (−40 to +302 °F)
Ambient temperaturePer TI Ambient temperature range tables
Display4-line illuminated graphic LCD with touch control; remote display available
CommunicationHART; PROFIBUS; Modbus; PROFINET; EtherNet/IP; WLAN; web server
ApprovalsCE; UKCA; Ex approvals per order code; Heartbeat Technology
NotesSpecs from E+H TI01272D/06/EN/12.26-00 (2026-06-22) and product page specs-at-a-glance.
Process PressureUp to 100 bar (1450 psi); PN 100 / Class 600 / 63K