Image unavailable
Image unavailable
Rosemount
Rosemount PowerVUE 6x10 Fan/Damper Actuator
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF
RFQ solo líneas BOM. Envíe para cotización de ingeniería.
Parámetros clave
Notes
Features/ordering from Emerson PowerVUE PDS 102-222.A01 PVD 610 section; stall/friction/time cross-checked to Emerson Hagan 6×10 torque family (same actuator construction stated in PowerVUE PDS).
Positioner Type
Rosemount PowerVUE PVD 610 — 6×10 torque-type floor-mounted fan/damper actuator (Hagan pneumatic drive + Fisher FieldVUE DVC6000)
Output Motion
80° shaft rotation (torque-type floor mount); family stroke class 6×10
Stall Torque
Family PowerVUE torque span up to 4,600 ft-lb; 6×10 Hagan-class stall ~1800 ft-lb (2441 N·m) at recommended 100 psig (same Hagan actuator construction cited in PowerVUE PDS)
Max Friction Load
Per Emerson Hagan 6×10 family literature ~450 ft-lb (610 N·m) class
Repeatability
Better than ±0.5% (PowerVUE PDS feature)
| Parámetro | Valor |
|---|---|
| Notes | Features/ordering from Emerson PowerVUE PDS 102-222.A01 PVD 610 section; stall/friction/time cross-checked to Emerson Hagan 6×10 torque family (same actuator construction stated in PowerVUE PDS). |
| Positioner Type | Rosemount PowerVUE PVD 610 — 6×10 torque-type floor-mounted fan/damper actuator (Hagan pneumatic drive + Fisher FieldVUE DVC6000) |
| Output Motion | 80° shaft rotation (torque-type floor mount); family stroke class 6×10 |
| Stall Torque | Family PowerVUE torque span up to 4,600 ft-lb; 6×10 Hagan-class stall ~1800 ft-lb (2441 N·m) at recommended 100 psig (same Hagan actuator construction cited in PowerVUE PDS) |
| Max Friction Load | Per Emerson Hagan 6×10 family literature ~450 ft-lb (610 N·m) class |
| Repeatability | Better than ±0.5% (PowerVUE PDS feature) |
| Full Stroke Time | Per Emerson Hagan 6×10 family ~5 s or less unloaded |
| Input Signal | Direct 4–20 mA with HART or FOUNDATION fieldbus via DVC6000 |
| Air Supply | Plant air via included filter/regulator (Style 4505C21G03); PowerVUE family 45–100 psig operating class |
| Air Consumption | Per Emerson Hagan 6×10 family ~1 scfm free air class |
| Temperature Limit | DVC6000 operating ambient −40 to +85 °C (−40 to +185 °F) per PowerVUE PDS DVC section; actuator heater option 115 VAC 150 W |
| Unit Weight | Shipping weight 275 lb / 125 kg (PowerVUE PDS ordering notes) |
| Options | Manual lock, mechanical air lock, 2× SPDT limit switches, digital EPT (HART), heater/thermostat |