Fluke

Fluke 85RF II High Frequency Probe

SKU · 32846 · 85RF II · Marca: Fluke
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Measuring range
0.25–30 Vrms RF AC (1:1 AC-to-DC conversion into 10 MΩ DC voltmeter)
Accuracy
Ratio accuracy at 25 MHz into 10 MΩ: ±0.5 dB above 0.5 V; ±1.0 dB below 0.5 V
Output
DC voltage equal to rms sine input (dual banana into DMM)
Supply
Passive probe (powered by host DMM input)
Electrical connection
Dual banana output for 10 MΩ ±10% DC voltmeter; ~9 pF input capacitance
Sensor type
High-frequency RF probe (100 kHz–500 MHz)
Descargar datasheet PDF
ParámetroValor
Measuring range0.25–30 Vrms RF AC (1:1 AC-to-DC conversion into 10 MΩ DC voltmeter)
AccuracyRatio accuracy at 25 MHz into 10 MΩ: ±0.5 dB above 0.5 V; ±1.0 dB below 0.5 V
OutputDC voltage equal to rms sine input (dual banana into DMM)
SupplyPassive probe (powered by host DMM input)
Electrical connectionDual banana output for 10 MΩ ±10% DC voltmeter; ~9 pF input capacitance
Sensor typeHigh-frequency RF probe (100 kHz–500 MHz)
NotesFrequency response relative to 25 MHz: ±0.5 dB to 80 MHz; ±2.0 dB to 200 MHz; ±3.5 dB to 300 MHz; ±4.5 dB to 400 MHz; ±5.5 dB to 500 MHz. Max input 30 Vrms / 200 VDC. Specs from Fluke 85RF II Instruction Sheet. Index name PVA-1500HE2 corrected to 85RF II.