Parámetros clave
Measuring range
0.25–30 Vrms RF AC (1:1 AC-to-DC conversion into 10 MΩ DC voltmeter)
Accuracy
Ratio accuracy at 25 MHz into 10 MΩ: ±0.5 dB above 0.5 V; ±1.0 dB below 0.5 V
Output
DC voltage equal to rms sine input (dual banana into DMM)
Supply
Passive probe (powered by host DMM input)
Electrical connection
Dual banana output for 10 MΩ ±10% DC voltmeter; ~9 pF input capacitance
Sensor type
High-frequency RF probe (100 kHz–500 MHz)
| Parámetro | Valor |
|---|---|
| Measuring range | 0.25–30 Vrms RF AC (1:1 AC-to-DC conversion into 10 MΩ DC voltmeter) |
| Accuracy | Ratio accuracy at 25 MHz into 10 MΩ: ±0.5 dB above 0.5 V; ±1.0 dB below 0.5 V |
| Output | DC voltage equal to rms sine input (dual banana into DMM) |
| Supply | Passive probe (powered by host DMM input) |
| Electrical connection | Dual banana output for 10 MΩ ±10% DC voltmeter; ~9 pF input capacitance |
| Sensor type | High-frequency RF probe (100 kHz–500 MHz) |
| Notes | Frequency response relative to 25 MHz: ±0.5 dB to 80 MHz; ±2.0 dB to 200 MHz; ±3.5 dB to 300 MHz; ±4.5 dB to 400 MHz; ±5.5 dB to 500 MHz. Max input 30 Vrms / 200 VDC. Specs from Fluke 85RF II Instruction Sheet. Index name PVA-1500HE2 corrected to 85RF II. |