Image unavailable
Image unavailable
Fluke
Fluke 1555 Insulation Resistance Tester
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF
RFQ solo líneas BOM. Envíe para cotización de ingeniería.
Parámetros clave
Measuring range
Insulation resistance up to 2 TΩ (1555); test voltages to 10 kV; selectable 250 V–1000 V in 50 V steps plus higher HV steps per TD
Accuracy
Per Fluke 1555/1550C Technical Data resistance accuracy bands (typically ±5% / ±20% by range/voltage)
Output
Digital display + bar graph to 2 TΩ; PI/DAR; Fluke Connect with ir3000 FC
Supply
12 V lead-acid rechargeable (Yuasa NP2.8-12); >750 tests between charges
Protection
IP40 (enclosure per OEM literature)
Approvals
CAT III 1000 V; CAT IV 600 V; IEC 61010
| Parámetro | Valor |
|---|---|
| Measuring range | Insulation resistance up to 2 TΩ (1555); test voltages to 10 kV; selectable 250 V–1000 V in 50 V steps plus higher HV steps per TD |
| Accuracy | Per Fluke 1555/1550C Technical Data resistance accuracy bands (typically ±5% / ±20% by range/voltage) |
| Output | Digital display + bar graph to 2 TΩ; PI/DAR; Fluke Connect with ir3000 FC |
| Supply | 12 V lead-acid rechargeable (Yuasa NP2.8-12); >750 tests between charges |
| Protection | IP40 (enclosure per OEM literature) |
| Approvals | CAT III 1000 V; CAT IV 600 V; IEC 61010 |
| Mounting | Portable benchtop/field case |
| Sensor type | High-voltage insulation resistance tester (megohmmeter) |
| Notes | Identity corrected from mis-seeded Yokogawa EY200 to Fluke 1555 per OEM product page + user SKU list. Specs from Fluke 1555/1550C Technical Data. |