Parámetros clave
Measuring range
±1.0° to ±90.0° full-scale input ranges (LCF-100/101 family)
Accuracy
Nonlinearity 0.02–0.05% FRO (range-dependent); resolution/threshold 1 µrad
Output
±5 VDC FRO; pin terminals (LCF-100) or 6-pin connector (LCF-101)
Supply
±12 to ±18 VDC; input current 15 mA max
Housing
Anodized aluminum (heavy construction)
Protection
Epoxy sealed (per OEM datasheet; not IP-rated)
| Parámetro | Valor |
|---|---|
| Measuring range | ±1.0° to ±90.0° full-scale input ranges (LCF-100/101 family) |
| Accuracy | Nonlinearity 0.02–0.05% FRO (range-dependent); resolution/threshold 1 µrad |
| Output | ±5 VDC FRO; pin terminals (LCF-100) or 6-pin connector (LCF-101) |
| Supply | ±12 to ±18 VDC; input current 15 mA max |
| Housing | Anodized aluminum (heavy construction) |
| Protection | Epoxy sealed (per OEM datasheet; not IP-rated) |
| Ambient temperature | Operating −40 to +80 °C; storage −40 to +90 °C |
| Approvals | RoHS-compliant version available |
| Sensor type | Fluid-damped flexure-suspension force-balanced (servo) single-axis inclinometer |
| Notes | OEM Jewell LCF-100/101 datasheet + product page. No Instrumart. |
| Bandwidth | 3–30 Hz (−3 dB), range-dependent |
| Shock | 1000 g, 1 ms, ½ sine |
| Vibration | 20 grms |
| Axes | 1 |