Parámetros clave

Measuring range
Transmitter for 1 or 2 ultrasonic sensors FDU90/91/91F/92/93/95; measuring range up to 45 m (148 ft) depending on sensor/medium; also open-channel flow
Accuracy
Per paired FDU sensor TI; transmitter provides linearization (≤32 points) and temperature-corrected time-of-flight
Output
1 or 2 active analog outputs 4–20 mA with HART (or 0–20 mA); 1/3/6 relays SPDT; PROFIBUS DP option
Supply
AC: 90–253 VAC 50/60 Hz ≤23 VA; DC option: 10.5–32 VDC ≤14 W (typ. 8 W)
Process connection
Transmitter only — sensors FDU* have process mounts; field housing or DIN-rail housing
Housing
Polycarbonate or aluminum field housing; DIN-rail housing
Descargar datasheet PDF
ParámetroValor
Measuring rangeTransmitter for 1 or 2 ultrasonic sensors FDU90/91/91F/92/93/95; measuring range up to 45 m (148 ft) depending on sensor/medium; also open-channel flow
AccuracyPer paired FDU sensor TI; transmitter provides linearization (≤32 points) and temperature-corrected time-of-flight
Output1 or 2 active analog outputs 4–20 mA with HART (or 0–20 mA); 1/3/6 relays SPDT; PROFIBUS DP option
SupplyAC: 90–253 VAC 50/60 Hz ≤23 VA; DC option: 10.5–32 VDC ≤14 W (typ. 8 W)
Process connectionTransmitter only — sensors FDU* have process mounts; field housing or DIN-rail housing
HousingPolycarbonate or aluminum field housing; DIN-rail housing
ProtectionField housing IP66/NEMA 4X; DIN-rail IP20; remote display IP65 front / IP20 rear
Media temperaturePer FDU sensor (transmitter is remote electronics)
Ambient temperature−40 to 60 °C (−40 to 140 °F); storage −40 to 60 °C
Display6-line plain-text display, 15 languages; envelope curves on display
CommunicationHART; PROFIBUS DP
ApprovalsATEX II 3D (optional aluminum field housing); CE
Hazardous areaOptional aluminum field housing ATEX II 3D
NotesTransmitter-only SKU — process_connection/wetted blank by design. Specs from TI00397F EN 2025-04-28.