Image unavailable
Image unavailable
Rosemount
Rosemount Oxymitter 4000 Oxygen Transmitter
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF
RFQ solo líneas BOM. Envíe para cotización de ingeniería.
Parámetros clave
Measuring range
Net O2 0–10% to 0–40% (Xi electronics offer 0–50%)
Accuracy
±0.75% of reading or ±0.05% O2, whichever is greater
Type
In-situ zirconium oxide oxygen transmitter for combustion flue gas (Oxymitter 4000)
Lowest Detectable Limit
0.02% O2
Response Time
Initial <3 s; T90 <8 s (process-dependent)
Process Temperature
Up to 1300 °F (700 °C); higher with optional bypass/jacket
| Parámetro | Valor |
|---|---|
| Measuring range | Net O2 0–10% to 0–40% (Xi electronics offer 0–50%) |
| Accuracy | ±0.75% of reading or ±0.05% O2, whichever is greater |
| Type | In-situ zirconium oxide oxygen transmitter for combustion flue gas (Oxymitter 4000) |
| Lowest Detectable Limit | 0.02% O2 |
| Response Time | Initial <3 s; T90 <8 s (process-dependent) |
| Process Temperature | Up to 1300 °F (700 °C); higher with optional bypass/jacket |
| Probe Lengths | 18 in to 18 ft insertion options |
| Housing | Type 4X (IP65/IP66) transmitter housing on probe or remote |
| Communications | 4–20 mA HART; FOUNDATION Fieldbus options; wireless via THUM |
| Diagnostics | Advanced sensor diagnostics; calibration-recommended alarm |
| Repairable | Fully field-repairable cell and heater/thermocouple |
| Document | PDS 00813-0100-4340 Rev AB + RM 00809-0100-4340 |