Parámetros clave

Measuring range
Gauge −14.7…30 to −14.7…10,000 psi; absolute 0…30 to 0…10,000 psia (ranges 1A–5A)
Accuracy
Ultra 0.025% of span; Classic 0.035% of span (performance class)
Accuracy % FS
0.025
Output
4–20 mA HART; WirelessHART; FOUNDATION Fieldbus
Supply
Per protocol/output option in PDS 00813-0100-4801
Process connection
½–14 NPT female; G½ A DIN 16288 male; autoclave F-250-C (range 5A); I-flange; assemble-to manifold/seal
Descargar datasheet PDF
ParámetroValor
Measuring rangeGauge −14.7…30 to −14.7…10,000 psi; absolute 0…30 to 0…10,000 psia (ranges 1A–5A)
AccuracyUltra 0.025% of span; Classic 0.035% of span (performance class)
Accuracy % FS0.025
Output4–20 mA HART; WirelessHART; FOUNDATION Fieldbus
SupplyPer protocol/output option in PDS 00813-0100-4801
Process connection½–14 NPT female; G½ A DIN 16288 male; autoclave F-250-C (range 5A); I-flange; assemble-to manifold/seal
Electrical connectionTerminal block in housing; remote display options M7/M8/M9
Wetted parts316L SST or Alloy C-276 isolating diaphragm (NACE options)
HousingAluminum or SST housing options per model code
ProtectionIP66/IP68 / Type 4X (housing-dependent; see PDS)
Media temperaturePer sensor module / fill fluid tables in PDS
Ambient temperaturePer electronics/housing tables in PDS
Pressure typegauge
DisplayOptional integral or remote display/interface
CommunicationHART; WirelessHART; FOUNDATION Fieldbus
ApprovalsSIL (option QT); ATEX/IECEx/FM/CSA options per model code
Hazardous areaMultiple hazardous-location approvals by option code
Fill fluidSilicone / inert options per sensor module
MountingIn-line direct process mount
NotesSpecs from Emerson PDS 00813-0100-4801 (3051S Series; In-line connection type T). Ultra/Classic performance classes; 200:1 / 150:1 rangedown.
Overpressure LimitPer range table in PDS 00813-0100-4801
Diaphragm SealAssemble-to Rosemount 1199 seal (B11)