Image unavailable
Image unavailable
Bacharach
Bacharach Informant 2 Leak Detector
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF
RFQ solo líneas BOM. Envíe para cotización de ingeniería.
Parámetros clave
Approvals
Combustibles path lab certified to UL913 intrinsically safe class (per OEM manual)
Type
Portable dual refrigerant / combustible gas leak detector (Informant 2)
Sensors
Interchangeable refrigerant (semiconductor) and combustibles semiconductor sensors
Sensitivity Refrigerant
0.5 oz/year (14 g/yr) of R-134a
Sensitivity Combustibles
50 ppm methane minimum
Response Time
0.2 seconds
| Parámetro | Valor |
|---|---|
| Approvals | Combustibles path lab certified to UL913 intrinsically safe class (per OEM manual) |
| Type | Portable dual refrigerant / combustible gas leak detector (Informant 2) |
| Sensors | Interchangeable refrigerant (semiconductor) and combustibles semiconductor sensors |
| Sensitivity Refrigerant | 0.5 oz/year (14 g/yr) of R-134a |
| Sensitivity Combustibles | 50 ppm methane minimum |
| Response Time | 0.2 seconds |
| Warm Up | 10 seconds |
| Power | Four AA alkaline batteries; about 4-5 hours typical intermittent use |
| Probe | Flexible gooseneck up to 20 in (508 mm); filtered tip; color-coded tips |
| Indicators | Visual LED bar + audible tick + flashing probe tip; mute; auto background compensation |
| Weight | 0.86 lb (0.39 kg) with batteries |
| Document | Bacharach Informant 2 Operation and Maintenance Instruction 0019-9211 Rev 9 (OEM archive) |