Image unavailable
Image unavailable
Endress+Hauser
Endress+Hauser Easytemp TMR35 Hygienic Compact RTD Thermometer
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF
RFQ solo líneas BOM. Envíe para cotización de ingeniería.
Parámetros clave
Measuring range
−50 to +150 °C (−58 to +302 °F); with extension neck up to +200 °C (+392 °F)
Accuracy
Class A per IEC 60751
Electrical connection
M12 4-pin connector
Protection
IP69K
Measuring Principle
Pt100 thin-film RTD per IEC 60751, Class A, 4-wire
Response Time
t50 = 1 s; t90 = 2 s (typical)
| Parámetro | Valor |
|---|---|
| Measuring range | −50 to +150 °C (−58 to +302 °F); with extension neck up to +200 °C (+392 °F) |
| Accuracy | Class A per IEC 60751 |
| Electrical connection | M12 4-pin connector |
| Protection | IP69K |
| Measuring Principle | Pt100 thin-film RTD per IEC 60751, Class A, 4-wire |
| Response Time | t50 = 1 s; t90 = 2 s (typical) |
| Process Pressure | Up to 100 bar (1450 psi) at 20 °C |
| Immersion Length | Variable installed lengths 40 to 600 mm (1.57 to 23.6 in) |
| Protection Tube Od | 3.0 mm or 6.0 mm |
| Material | 1.4404 (316L) stainless steel; entirely stainless construction |
| Surface Finish | Ra 0.4 µm or 0.8 µm |
| Hygiene Approvals | 3-A, EHEDG; ASME BPE / FDA / EC 1935/2004 stated on TI |
| Other Approvals | Marine (DNV GL); NAMUR NE21/NE43 failure information |