Badger Meter

Badger Meter Recordall Turbo Series Flow Meters

SKU · 48932 · Recordall Turbo Series Flow Meters · Marca: Badger Meter
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Product Family
Recordall Turbo Series direct-coupled turbine meters (Models 160–6200)
Line Sizes
1-1/2 in. to 12 in. (40–300 mm)
Flow Range
Typical operating about 2.5–8,800 gpm (0.6–1,998 m³/h) across sizes
Max Operating Pressure
150 psi (10 bar)
Temperature
Up to 120 °F (49 °C) cold-water service
Accuracy Standard
Meets/exceeds AWWA C701 Class II; exceptional registration across low/normal/max continuous flows
Descargar datasheet PDF
ParámetroValor
Product FamilyRecordall Turbo Series direct-coupled turbine meters (Models 160–6200)
Line Sizes1-1/2 in. to 12 in. (40–300 mm)
Flow RangeTypical operating about 2.5–8,800 gpm (0.6–1,998 m³/h) across sizes
Max Operating Pressure150 psi (10 bar)
TemperatureUp to 120 °F (49 °C) cold-water service
Accuracy StandardMeets/exceeds AWWA C701 Class II; exceptional registration across low/normal/max continuous flows
TechnologyFloating-rotor turbine; direct magnetic drive to sealed register/encoder
MaterialsLead-free bronze alloy (1-1/2–10 in.); cast iron 12 in.; NSF/ANSI/CAN 61 & 372
StrainerIntegral strainer standard on 1-1/2 in.; optional 2–4 in.; external strainers 2–12 in.
Reading SystemsCompatible with Badger Meter AMR/AMI and approved reading technologies
ApplicationsCold water commercial/industrial: hotels, apartments, irrigation, process plants
DocumentRTS-DS-00320-EN-11 (August 2026)