Parámetros clave
Accuracy
±3% of flow value at flow rate > 0.3 m/s
Measuring Method
Ultrasonic transit-time
Flow Range
0.1–10 m/s (0.3–32 ft/s)
Repeatability
±0.5% of measured value
Response Time
< 500 ms
Pipe Od
22–180 mm (¾–7 in) depending on material
| Parámetro | Valor |
|---|---|
| Accuracy | ±3% of flow value at flow rate > 0.3 m/s |
| Measuring Method | Ultrasonic transit-time |
| Flow Range | 0.1–10 m/s (0.3–32 ft/s) |
| Repeatability | ±0.5% of measured value |
| Response Time | < 500 ms |
| Pipe Od | 22–180 mm (¾–7 in) depending on material |
| Pipe Materials | PVDF, PP-H, PE, PB, ABS, PVC, CPVC, steel, iron, stainless steel 316 |
| Pipe Temperature | 0 to +85 °C |
| Operating Temperature | 0 to +50 °C |
| Power Supply | 12–24 V AC/DC; max 7 VA |
| Analog Output | 4–20 mA, 0.1% resolution, load max 620 Ω |
| Pulse Output | Opto-isolated MOSFET, 1–166 pps programmable, max 200 Hz |
| Modbus | RTU RS485, baud 1200–38400 |
| Housing | Polycarbonate, 250 × 48 × 90 mm, 0.5 kg; LCD 2×16 with backlight |