Panametrics AquaTrans AT600 Ultrasonic Flow Meter

SKU · 40940 · AquaTrans AT600 · Marca: Panametrics
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Accuracy
±1% of reading (≥2 in and >1 ft/s); ±2% (<2 in and >1 ft/s); ±0.5% in field calibration
Supply
Standard 85–265 VAC 50/60 Hz; optional 12–28 VDC
Display
Graphic LCD 128 × 64 pixels; green/red error indicator
Measurement Principle
Patented Correlation Transit-Time ultrasonic (clamp-on)
Fluid Types
Acoustically conductive liquids: potable water, wastewater, sewage, cooling/heating, irrigation
Pipe Sizes
0.5 to 300 in (15 to 7600 mm)
Descargar datasheet PDF
ParámetroValor
Accuracy±1% of reading (≥2 in and >1 ft/s); ±2% (<2 in and >1 ft/s); ±0.5% in field calibration
SupplyStandard 85–265 VAC 50/60 Hz; optional 12–28 VDC
DisplayGraphic LCD 128 × 64 pixels; green/red error indicator
Measurement PrinciplePatented Correlation Transit-Time ultrasonic (clamp-on)
Fluid TypesAcoustically conductive liquids: potable water, wastewater, sewage, cooling/heating, irrigation
Pipe Sizes0.5 to 300 in (15 to 7600 mm)
Pipe MaterialsAll metals and most plastics; lined pipes supported
OutputsVelocity, volumetric, and totalized flow; Modbus
EnclosureEpoxy-coated aluminum weatherproof Type 4X / IP67
Dimensions6.6 × 5.0 × 2.4 in (168 × 128 × 61 mm); weight 3.5 lb (1.5 kg)
Power Consumption10 W in-rush; 5 W normal operation
Operating Temperature–4 to 131 °F (–20 to 55 °C)
InstallationFour-step clamp-on; typically 10D upstream / 5D downstream straight run
Special FeaturesPermanent solid couplant option; automatic fluid property adjustment