Rosemount

Rosemount 8800D Series Vortex Flow Meter

SKU · 31616 · 8800D · Marca: Rosemount
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Measuring range
Line sizes ½…12 in (15…300 mm) flanged; reducer 1…14 in (25…350 mm); flow range per sizing (Reynolds-dependent); liquids Rn>20000, gas/steam Rn>15000
Accuracy
Liquids ±0.65% of rate (digital/pulse, Rn>20000); gas/steam ±1.0% of rate (Rn>15000); analog add ±0.025% of span; reducer 6–12 in liquids ±1.0% / gas ±1.35%
Output
4–20 mA HART; FOUNDATION Fieldbus; Modbus RS-485; pulse; optional MultiVariable (MTA/MPA/MCA)
Supply
Per transmitter option (loop-powered HART/FF typical industrial 10.5–42 Vdc class; see PDS power tables)
Process connection
Wafer, flanged, dual, quad, weld end, threaded end, reducer, high-pressure designs; flange ratings per order
Wetted parts
316/316L SST (code S) standard; options Duplex/Super Duplex, Nickel Alloy, etc. per wetted material code
Descargar datasheet PDF
ParámetroValor
Measuring rangeLine sizes ½…12 in (15…300 mm) flanged; reducer 1…14 in (25…350 mm); flow range per sizing (Reynolds-dependent); liquids Rn>20000, gas/steam Rn>15000
AccuracyLiquids ±0.65% of rate (digital/pulse, Rn>20000); gas/steam ±1.0% of rate (Rn>15000); analog add ±0.025% of span; reducer 6–12 in liquids ±1.0% / gas ±1.35%
Output4–20 mA HART; FOUNDATION Fieldbus; Modbus RS-485; pulse; optional MultiVariable (MTA/MPA/MCA)
SupplyPer transmitter option (loop-powered HART/FF typical industrial 10.5–42 Vdc class; see PDS power tables)
Process connectionWafer, flanged, dual, quad, weld end, threaded end, reducer, high-pressure designs; flange ratings per order
Wetted parts316/316L SST (code S) standard; options Duplex/Super Duplex, Nickel Alloy, etc. per wetted material code
HousingAluminum or SST transmitter housing options; CSA Type 4X / IP66 enclosure rating
ProtectionCSA Type 4X; IP66 (transmitter housing)
Media temperatureStandard and extended sensor process temperature ranges by wetted material / PED (see PDS Table 10); ambient interdependent with process (Figure 3)
Ambient temperaturePer PDS ambient/process limit curves and hazardous-area T-class tables
DisplayOptional LCD (flow, totalizer, mA, temperature/pressure for MV)
CommunicationHART; FOUNDATION Fieldbus; Modbus RS-485
ApprovalsSIL2; SIL3; ATEX; IECEx; FM; CSA; PED; CE
Hazardous areaUS/Canada/ATEX/IECEx and other hazardous area approvals selectable in ordering (E5 etc.)
NotesSpecs from Emerson PDS 00813-0100-4004 Rev KK Nov 2024. Sizing required for exact min/max flow.
Repeatability±0.1% of actual flow rate
Stability±0.1% of rate over one year